Download PFG-691
Transcript
Model 691 Technical Data for CE Marked Products Nominal Heat Input: (Net) Natural (I2H) = 26,4 kW (90,000 Btu/h) Liquid Propane (I3P) = 27,0 kW (92,000 Btu/h) Nominal Heat Input: (Gross) Natural (I2H) = 29,3 kW (100,000 Btu/h) Liquid Propane (I3P) = 29,3 kW (100,000 Btu/h) Supply Pressure: Natural (I2H) = 20 mbar Liquid Propane (I3P) = 37/50 mbar Test Point Pressure: Natural (I2H) = 8,7 mbar Liquid Propane (I3P) = 25 mbar Injector Size: Natural (I2H) = 2,51 mm Liquid Propane (I3P) = 1,04 mm This appliance must be installed in accordance with the manufacturer’s instructions and the regulations in force and only used in a suitable ventilated location. Read the instructions fully before installing or using the appliance. Datos Tecnicos Para Products CE Consumo Calorico Nominal: (Neto) Gas Natural (I2H) = 26,4 kW (90,000 Btu/h) Propano Licuado (I 3P) = 27,0 kW (92,000 Btu/h) Consumo Calorico Nominal: (Bruto) Gas Natural (I2H) = 29,3 kW (100,000 Btu/h) Propano Licuado (I3P) = 29,3 kW (100,000 Btu/h) Presion De Alimentacion: Gas Natural (I2H) = 20 mbar Propano Licuado (I3P) = 37/50 mbar Presion En Ez Punto De Prueba: Gas Natural (I2H) = 8,7 mbar Propano Licuado (I3P) = 25 mbar Diámetro Boquilla: Gas Natural (I2H) = 2,51 mm Propano Licuado (I3P) = 1,04 mm Este equipo debe instalarse únicamente en un recinto adecuadameute ventilado y conforme a las indicaciones del fabricante y a las normas vigentes. Lea completamente las instrucciones antes de instalar o usar este equipo.