Download PFG-691
Transcript
Model 691 3-16. PROGRAMMING (Continued) After the alarm time is set, press and “ALARM” and “TYPE” flashes in the display, with the alarm type on the right side of the display. “TIME”, “SHAKE”, “STIR”, “ADD”, and “LID” can be set by pressing . An alarm sounds and alarm type flashes, prompting the operator to shake the basket, stir the product, or add product. If “TIME” is selected, the time remaining flashes in the display. If “LID” is selected, “CLOSE LID” flashes in the display. The timer countdown is paused until the lid is closed and is pressed to restart the timer. Up to four alarms can be programmed. After the first one is set, the other alarms can be accessed by pressing again. 11. Press and release until “QUALITY TMR” shows in the display along with the preset holding time. Press and release to adjust the holding time, up to 59:59. To exit the Program Mode at any time, press and hold for 2 seconds. 12. Press and release and “LOAD COMP” shows in the display along with the load compensation value. This automatically adjusts the time to account for the size and temperature of the cooking load. Press and release to change this value to a max. of 20 and a min. of 0 or “OFF”. Preset at factory at 5. 13. 3-30 Press and release and “LCOMP REF” shows in the display (if load compensation is set to “OFF”, then “_ _ _” shows in display) along with the load compensation average temperature. This is your average cooking temperature for the products you cook. The timer speeds up at temperature above this setting and slows down at temperatures below this setting. Press and release to change this value. 803