Download Operator`s Manual
Transcript
Second Edition · Eighth Printing Operator's Manual FUNCTION TESTS Test the Tilt Sensor At the Platform Controls 9 Pull out the platform red Emergency Stop button to the on position. Turn the key switch to platform control. Test Emergency Stop 10 Open the tank side turntable cover and locate the tilt sensor next to the control box. 11 Press down one side of the tilt sensor. 15 Turn the key switch to platform control and restart the engine. 16 Push in the platform red Emergency Stop button to the off position. Result: The engine should turn off and all functions should not operate. Result: The alarm, located in the platform, should sound. 17 Pull out the red Emergency Stop button and restart the engine. Test Auxiliary Controls Test the Hydraulic Oil Return Filter 12 Turn the key switch to ground control and shut the engine off. 18 Move the engine idle select switch to high idle (rabbit symbol). 13 Pull out the red Emergency Stop button to the on position. 19 Locate and check the hydraulic filter condition indicator. 14 Simultaneously hold the auxiliary power switch on and activate each boom function toggle switch. Result: The filter should be operating with the plunger or the needle in the green area. Note: To conserve battery power, test each function through a partial cycle. 20 Move the engine idle select switch to foot switch activated high idle (rabbit and foot switch symbol). Result: All boom functions should operate. Test the Horn 21 Push the horn button. Result: The horn should sound. Part No. 43645 Genie S-40 & Genie S-45 17