Download MAINTENANCE INTERVALS - Safety

Transcript
SEBU8079-11
159
Maintenance Section
Camera - Clean
Display
Illustration 145
g01223034
WAVS display
Illustration 144
g01417276
3. Remove the filter element.
4. Clean the filter elements with compressed air.
Use a soft, damp cloth in order to clean the display.
The display has a soft plastic surface that can be
easily damaged by an abrasive material. The display
is not sealed. Do not immerse the display with
liquid.
Camera
You can also wash the filter elements in a solution
of warm water with a nonsudsing household
detergent. Rinse the filter elements in clean water.
Air dry the filter elements thoroughly.
5. Install the filter element and the filter cover.
Replace any filter elements that are worn or
damaged.
Note: Make sure that the seals on the filter elements
next to the seat are facing toward the parking brake
lever when you install the filter elements.
i02816405
Camera - Clean
(If Equipped)
SMCS Code: 7348-070
In order to maintain sufficient vision, keep the Work
Area Vision System (WAVS) camera lens and the
display clean.
Illustration 146
g01223051
The WAVS camera is located on the rear of the machine in the
center of the fan guard.
Use a damp cloth or water spray in order to clean
the camera lens. The camera is a sealed unit. The
camera is not affected by high pressure spray.
The camera is equipped with an internal heater to
help counteract the effects of condensation, snow,
or ice.
Note: For more information on WAVS, refer to
Operation and Maintenance Manual, SEBU8157,
“Work Area Vision System”.