Maintenance Section
Axle Oscillation Bearings - Lubricate
Illustration 118
SEBU8079-11
g01264369
Rear Differential and Final Drive Filler Plug
Note: Wipe the covers and surfaces around openings
before you remove the filler plug.
7. Remove the filler plugs for both differentials. Fill
the differentials with oil. Maintain the oil level at
the bottom of the filler plug hole.
8. Install the filler plugs for each differential. Operate
the machine for a few minutes and allow the oil
to flow completely through the axles. Remove
the filler plugs and check the oil level. Add oil, if
necessary.
Reference: Refer to Operation and Maintenance
Manual, “Lubricant Viscosities” for the proper oil.
Reference: Refer to Operation and Maintenance
Manual, “Capacities (Refill)” for the amount of oil.
9. Clean the filler plugs and install the filler plugs.
Illustration 119
g01448235
Wipe off the fittings before you apply any lubricant.
Apply lubricant through two remote fittings near the
articulation hitch on the right side of the machine.
i01698523
Backup Alarm - Test
SMCS Code: 7406-081
Turn the engine start switch key to ON in order to
perform the test.
Apply the service brake. Move the transmission
direction control lever to REVERSE position.
i02910320
Axle Oscillation Bearings Lubricate
SMCS Code: 3268-086-BD; 3278-086-BD
Crushing Hazard. Insure that the machine ignition
switch is in the OFF position and that the parking
brake is engaged before entering the articulation
area. Failure to do so could result in serious injury
or death.
The backup alarm should immediately sound.
The backup alarm will continue to sound until the
transmission direction control lever is moved to the
NEUTRAL position or to the FORWARD position.
The backup alarm is mounted in the back of the
machine behind the rear grill.