Download TRITON ERROR CODES

Transcript
TRITON ERROR CODES
Error Code
MODEL SERIESDescriptionResolution
159
8100, 9100, 9110, 9600, 9610, 9615, Electronic journal 1. Inspect main board to electronic journal communication cable
9640, 9650, 9700, 9710, 9705, 9750, test feature failed for damage. Make sure the connectors are seated securely on
RL5000 (SDD), RL5000 (TDM), the main board and on the electronic journal.
RL5000 (NMD), FT5000 RT2000,
2. If it is necessary to check continuity of the cable assembly, refer
9800, 9840, 9850, MAKO to the appropriate ATM Service Manual for pin out of the cable
assembly.
3. Inspect electronic journal to dispenser communication cable for
damage. Make sure the connectors are seated securely on the
main board and on the electronic journal.
4. If it is necessary to check continuity of the cable assembly, refer
to the appropriate ATM Service Manual for pin out of the cable
assembly.
5. If the cables are undamaged, the main board or electronic
journal may be defective.
160
8100, 9100, 9110, 9600, 9610, 9615, Electronic journal 1. Inspect main board to electronic journal communication cable
9640, 9650, 9700, 9710, 9705, 9750, set featured failed for damage. Make sure the connectors are seated securely on
RL5000 (SDD), RL5000 (TDM), the main board and on the electronic journal.
RL5000 (NMD), FT5000 RT2000,
2. If it is necessary to check continuity of the cable assembly,
9800, 9840, 9850, MAKO refer to Appendix B for pin out of the cable assembly.
3.Inspect electronic journal to dispenser communication cable for
damage. Make sure the connectors are seated securely on the
main board and on the electronic journal.
4. If it is necessary to check continuity of the cable assembly, refer
to the appropriate ATM Service Manual for pin out of the cable
assembly.
5. If the cables are undamaged, the main board or electronic
journal may be defective.
161
8100, 9100, 9110, 9600, 9610, 9615, Electronic journal 1. Inspect main board to electronic journal communication cable
9640, 9650, 9700, 9710, 9705, 9750,
clear feature failed for damage. Make sure the connectors are seated securely on
RL5000 (SDD), RL5000 (TDM), the main board and on the electronic journal.
RL5000 (NMD), FT5000 RT2000, 2. If it is necessary to check continuity of the cable assembly, refer
9800, 9840, 9850, MAKO to the appropriate ATM Service Manual for pin out of the cable
assembly.
3. Inspect electronic journal to dispenser communication cable for
damage. Make sure the connectors are seated securely on the
main board and on the electronic journal.
4. If it is necessary to check continuity of the cable assembly, refer
to the appropriate ATM Service Manual for pin out of the cable
assembly.
5. If the cables are undamaged, the main board or electronic
journal may be defective.