Download TRITON ERROR CODES
Transcript
TRITON ERROR CODES Error Code MODEL SERIESDescriptionResolution 159 8100, 9100, 9110, 9600, 9610, 9615, Electronic journal 1. Inspect main board to electronic journal communication cable 9640, 9650, 9700, 9710, 9705, 9750, test feature failed for damage. Make sure the connectors are seated securely on RL5000 (SDD), RL5000 (TDM), the main board and on the electronic journal. RL5000 (NMD), FT5000 RT2000, 2. If it is necessary to check continuity of the cable assembly, refer 9800, 9840, 9850, MAKO to the appropriate ATM Service Manual for pin out of the cable assembly. 3. Inspect electronic journal to dispenser communication cable for damage. Make sure the connectors are seated securely on the main board and on the electronic journal. 4. If it is necessary to check continuity of the cable assembly, refer to the appropriate ATM Service Manual for pin out of the cable assembly. 5. If the cables are undamaged, the main board or electronic journal may be defective. 160 8100, 9100, 9110, 9600, 9610, 9615, Electronic journal 1. Inspect main board to electronic journal communication cable 9640, 9650, 9700, 9710, 9705, 9750, set featured failed for damage. Make sure the connectors are seated securely on RL5000 (SDD), RL5000 (TDM), the main board and on the electronic journal. RL5000 (NMD), FT5000 RT2000, 2. If it is necessary to check continuity of the cable assembly, 9800, 9840, 9850, MAKO refer to Appendix B for pin out of the cable assembly. 3.Inspect electronic journal to dispenser communication cable for damage. Make sure the connectors are seated securely on the main board and on the electronic journal. 4. If it is necessary to check continuity of the cable assembly, refer to the appropriate ATM Service Manual for pin out of the cable assembly. 5. If the cables are undamaged, the main board or electronic journal may be defective. 161 8100, 9100, 9110, 9600, 9610, 9615, Electronic journal 1. Inspect main board to electronic journal communication cable 9640, 9650, 9700, 9710, 9705, 9750, clear feature failed for damage. Make sure the connectors are seated securely on RL5000 (SDD), RL5000 (TDM), the main board and on the electronic journal. RL5000 (NMD), FT5000 RT2000, 2. If it is necessary to check continuity of the cable assembly, refer 9800, 9840, 9850, MAKO to the appropriate ATM Service Manual for pin out of the cable assembly. 3. Inspect electronic journal to dispenser communication cable for damage. Make sure the connectors are seated securely on the main board and on the electronic journal. 4. If it is necessary to check continuity of the cable assembly, refer to the appropriate ATM Service Manual for pin out of the cable assembly. 5. If the cables are undamaged, the main board or electronic journal may be defective.