Specifications
Model Covered in this Specification CF2
Gas Connection
400mm GAS FRYER (Single Tank - 18 Ltr).
Gas supply connection point is located 40mm from
the right hand side, 24mm from the rear and 221mm
from the floor.
- Flexible Hose Connection
If a Gas Hose assembly is used to connect this
appliance, the hose and all fittings must have a
minimum ¾” (Natural Gas) or ½” (LPG) inside bore
diameter to ensure gas flow rate capacity
required by this appliance is achieved.
This must be verified by the operating pressure
testing at the maximum gas supply demand
condition.
The Gas Hose assembly should also be classified
for use in the commercial kitchen conditions, the
appliance will be used in.
Recommended Gas Hose Assembly Specification:
- AS/NZS 1869 Class B or D compliant or equivalent,
that meets the following requirements:-
General
A commercial gas fired fryer fitted with a 90MJ/hr,
Multi Jet Target ’U’ Burner and pilot burner,
controlled by a single gas controller which controls
both pilot and main burner. It is available in single
model type only.
This Fryer is fitted with an Over Temperature Safety
Cut Out system with Full Flame Failure Safety
Controls.
An open tank design to make cleaning a simple
and easy task.
3
Class
Max Working
Pressure
at 23 ± 2ºC
B
7.0 kPa
D
2.6 MPa
Working
Temperature
Range
Resistance to Oil
- 20ºC to + 125ºC
Oil resistant lining
and cover.