Part 2 Specifications Gas Supply Requirements - Non UK Models: Input Rating (N.H.G.C.) Supply Pressure Gas Natural LP Gas / Butane Town Gas (**) 90 MJ/hr (85,300 Btu/hr) 90 MJ/hr 90 MJ/hr (85,300 Btu/hr) (85,300 Btu/hr) 1.13 - 2.0 kPa (4.5” - 8.0” w.c.) 2.75 - 3.0 kPa (11” - 12” w.c.) 0.75 - 1.5 kPa (3” - 6” w.c.) 0.90 kPa (*) 2.5 kPa (*) 0.39 kPa (*) (3.6” w.c.) (10.0” w.c.) (1.6” w.c.) Burner Operating Pressure Gas Connection ¾” BSP Male - UK Models: Appliance Classification: Category: II2H3P (20, 37). Heat Input (nett) Gas Rate Supply Pressure Burner Operating Pressure Gas Connection Flue Type: A1. Natural Gas (G20) Propane (G31) 22.5 kW 2.26 m3/hr 22.5 kW 1.75 kg/hr 20 mbar 37 mbar 9.0 mbar (*) 25 mbar (*) 3/ 4” BSP Male NOTE: (*) Measure the Burner Operating Pressure at the Operating Pressure Test Point (Lower - Out) on the Gas Control Valve, with Main Burner operating. (**) TOWN GAS Only - Gas Control Valve - Operating Pressure Adjusting Screw should be replaced with the Knock Out Plug supplied in Town Gas Kit and the operating pressure adjusted at the External Gas Pressure Regulator. Both the Knock Out Plug and External Regulator are supplied in the Town Gas Conversion Kit. Refer to the ‘Gas Conversion and Specifications’ section of this manual for further details. 4