Download TK-3107
Transcript
TK-3107 TK-3107 ADJUSTMENT ADJUSTMENT Use the KPG-55D programming software for adjustment of the next item in PC MODE (see page 2). Squelch Level, Transmit frequency, DQT Balance, RF Power, QT Deviation, DQT Deviation, Battery Level BPF-Wave Section common to the transmitter and receiver (VCO) Item 1. Setting 2. VCO lock voltage Condition 1) Power supply voltage Battery teriminal:7.5V 1) CH: TX high 2) CH: RX high 3) CH: TX low 4) CH: RX low Measurement Test equipment Terminal Digital voltmeter CV Parts TC1 TC2 Adjustment Method Specifications/ Remarks ±0.1V ±0.1V 3.7V 3.7V Check more than 1.0V Receiver Section Item 1. Bandpass filter Condition 1) CH: RX center 2) Tra generator output -40dBm Connect the spectrum analyzer to TP2 terminal. 2. AF level 1) CH: RX center SSG output: -53dBm (501µV) MOD: 1kHz DEV: ±3.0kHz (Wide) : ±1.5kHz (Narrow) 3. Sensitivity 1) CH: RX center CH: RX LO CH: RX Hi SSG ouput: -116dBm (0.35µV) MOD: 1kHz DEV: ±3.0kHz (Wide) : ±1.5kHz (Narrow) 4. Squelch 1) CH: RX center Level MONI: ON (PC MODE) 2) Level 9 SSG output: -117dBm 3) Level 3 SSG output: -125dBm(0.126µV) Measurement Test equipment Terminal Parts Tra generator ANT TC201 Spectrum analyzer TP2 TC202 TC203 Adjustment Method Adjust the frequency so that it becomes the spectrum waveform shown in Fig.1. SSG Oscilloscope AF. V. M Distortion meter Adjust to the MAX AF level ANT SP L212 Specifications/ Remarks Check SINAD: 12dB or higher Level 9 Adjust to close the squelch. The squelch must be closed. Level 3 Adjust to close the squelch. The squelch must be closed. Measurement Test equipment Terminal Parts Frequency ANT PC key counter Adjustment Method Adjust to center frequency Specifications/ Remarks within ± 100Hz Modulation analyzer or linear detector (LPF: 3kHz) Oscilloscope Rectify the waveform to square wave PC key Fig. 1 Transmitter section Item Condition 1. Transmit 1) CH: TX center frequency PTT: ON (PC MODE) 2. DQT/QT 1) CH: TX center Balance (PC MODE) 3. Power 1) CH:TX LOW (PC MODE) Battery terminal: 7.5V PTT: ON 4. MAX DEV 1) CH: TX center AG: 1kHz/120mV PTT: ON 5. MIC SENS 1) CH: TX center AG: 1kHz/12mV 6. QT DEV 1) CH: TX high (PC MODE) QT: 67.0Hz 7. DQT DEV 1) DQT:023N center (PC MODE) 8. Battery 1) Battery terminal: 5.8V Level (PC MODE) VR500 Power meter Ammeter Modulation ANT analyzer or linear MIC detector (LPF:15kHz) Oscilloscope AG AF. V. M VR501 Modulation ANT analyzer or linear detector (LPF:3kHz) Oscilloscope AG AF. V. M Modulation analyzer or linear detector (LPF:3kHz) Oscilloscope Digital voltmeter BATT PC key PC key PC key Adjust it to 4.1W ±0.1W Adjust it to ± 4.2kHz (Wide) Narrow check (+, - Peak whichever is Maximum) Check (+, - Peak whichever is Maximum) ±100Hz Adjust it to ± 0.75kHz (Wide) Adjust it to ± 0.35kHz (Narrow) Adjust it to ± 0.75kHz (Wide) Adjust it to ± 0.35kHz (Narrow) Adjust so that the LED flashes. ±1.8kHz~2.2kHz ±2.2kHz~3.6kHz: (Wide) ±1.1kHz~1.8kHz: (Narrow) ±50Hz ±50Hz ±50Hz ±50Hz The LED must flash. 21 22