Use and Installation Recommendations:
1.0 Install an external pilot feed adapter on each Magnum Cv valve in the system.
2.0 Install a shut-off valve and a screen/filter in the separate source feed line, if possible. Multi-tank systems
should have a shut-off valve in the feed line to each unit in the system to facilitate servicing.
3.0 Systems with a separate water source located greater than 10 feet from the system should have a water line
of at least 1/2 to 3/4-inch in size, installed to within 6 - 8 feet of the system; then the
1/4-inch tubing can be fed to each Magnum Cv in the system from that point. Again, each feed line should
be provided with a shut-off valve to facilitate servicing.
The pilot feed adapter has been designed to allow the use of the Magnum Cv Series in a multitude of varying
commercial and industrial water treatment applications. Need help with an applications problem? Call
Osmonics – we have the SOLUTION!