Download Yokogawa WT110 Digital Power Meter
Transcript
5.1 Measuring/Displaying Voltage, Current and Active Power Explanation Continuous Maximum Allowable Input • Voltage : peak voltage is 1.5kV, or the RMS value is 1.0kV, whichever is less. • Current : peak current is 100A or the RMS value is 30A, whichever is less. In case of external sensor input, the peak value is 5 times the measurement range or less. Maximum Reading of the Display and Units • Maximum reading • Units • Prefix : for voltage, current and power, each 9999 : V (voltage), A (current), W (power) : m, k, M Selecting the Display Function The following selections are available. • V : voltage will be displayed • A : current will be displayed • W : power will be displayed Selecting the Input Element The type of input element which can be selected depends on the model number. Make your selection after having verified your model number. • 1/2/3 : Displays the measurement values of element 1/2/3 •∑ : Displays according to the wiring method, and is as follows. Wiring method ΣV V1+V3 1Φ3W 2 ΣA A1+A3 V1+V3 A1+A3 2 2 3Φ3W 3Φ4W 3V3A 5-2 V1+V2+V3 3 V1+V2+V3 3 2 ΣW ΣVA Σvar W1+W3 V1A1+V3A3 var1+var3 W1+W3 A1+A2+A3 W1+W2+W3 3 A1+A2+A3 W1+W3 3 Wiring method ΣPF Σdeg 1Φ3W 3Φ3W 3Φ4W 3V3A ΣW ΣVA cos-1ΣPF 3 ( V1A1+V3A3 ) 2 V1A1+V2A2+V3A3 var1+var3 var1+var2+var3 3 ( ) var1+var3 3 V1A1+V2A2+V3A3 IM 253401-01E