Download caution! - Climatemaster

Transcript
THE SMART SOLUTION FOR ENERGY EFFICIENCY
Tr a n q u i l i t y ® 2 0 ( T S ) S e r i e s
R e v. : 0 7 / 1 7 / 1 3
Model Nomenclature - General Overview
1 2
3
4 5 6
7
9
TS
V
0 24
A G C 1
8
10
11
12
13
14
15
0 A L T S
SERIES
STANDARD
TS = Tranquility® Single Stage
S = Standard
CONFIGURATION
SUPPLY AIR FLOW &
MOTOR CONFIGURATION
V = Vertical Up
H = Horizontal
D = Vertical Down
Option
T
D
B
S
V
U
Y
Z
K
N
P
W
UNIT SIZE
006 - E,G
009 - E,G
012 - E,G
018 - E, G
024 - E, G, H, F
030 - E, G, H, F
036 - E, G, H, F
042 - G, H, F, N
048 - G, H, F, N
060 - G, H, F, N
070 - G, H, F, N
Supply Configuration
Motor
Top
TSV
PSC
Down
TSD
PSC
Back
TSH
PSC
Straight
TSH
PSC
Top
TSV
PSC Hi Static
PSC Hi Static
TSD
Down
PSC Hi Static
TSH
Back
PSC Hi Static
TSH
Straight
Top
TSV
ECM
ECM
TSD
Down
ECM
TSH
Back
ECM
TSH
Straight
REVISION LEVEL
A = 006-070
B = 018
RETURN AIR FLOW CONFIGURATION
VOLTAGE
L = Left Return
R = Right Return
G = 208-230/60/1
E = 265/60/1
H = 208-230/60/3
F = 460/60/3
N = 575/60/3
HEAT EXCHANGER OPTIONS
Non Coated Air Coil
Coated Air Coil
Copper Cupro-Nickel Copper Cupro-Nickel
C
N
A
J
Standard
Motorized Valve
T
S
U
W
®
E
P
D
F
ClimaDry
CONTROLS
C = CXM
D = DXM
L= CXM w/LON
M = DXM w/LON
N = CXM w/MPC
P = DXM w/MPC
A = CXM
B = DXM
E = CXM w/LON
K = DXM w/LON
R = CXM w/MPC
S = DXM w/MPC
}
w/Disconnect
WATER CIRCUIT OPTIONS
0 = None
2 = HWG (Coil Only)
5 = Internal Secondary Pump
6 = HWG (Coil Only) w/Auto Flow Regulator 2.5 GPM/Ton
7 = HWG (Coil Only) w/Auto Flow Regulator 3.0 GPM/Ton
8 = Auto Flow Regulator 2.5 GPM/Ton
9 = Auto Flow Regulator 3.0 GPM/Ton
Cabinet
OPTION RANGE
1
A
J
K
2
C
L
M
3
E
N
P
4
G
R
S
ULTRA
QUIET
NO
YES
NO
YES
1” FILTER 2” FILTER 1” FILTER 2” FILTER
RAIL
RAIL
FRAME
FRAME
YES
NO
NO
YES
NO
YES
NO
NO
NO
YES
YES
NO
NO
YES
NO
YES
NO
NO
NO
YES
YES
NO
NO
YES
NO
NO
YES
NO
NO
YES
YES
NO
NO
YES
NO
YES
NO
YES
NO
NO
Note: Above model nomenclature is a general reference. Consult individual engineering guides for detailed information.
ClimaDry® II Option Notes:
1. Unit must have DXM control option. 460 volt unit units require a four wire power supply with neutral.
2. ClimaDry® II may not be combined with motorized water valve, internal secondary circulating pump, or automatic
flow regulator options.
3. Unit minimum entering air temperature while in the dehumidification, cooling, or continuous fan modes is
70ºF DB/61ºF WB. Operation below this minimum may result in nuisance faults.
4. A thermostat with dehumidification mode or thermostat and separate humidistat/dehumidistat is required for
activation and control of ClimaDry® II.
5. Downflow and 575 volt units are not eligible for ClimaDry® II.
c l i m a t e m a s t e r. c o m