Download caution! - Climatemaster
Transcript
THE SMART SOLUTION FOR ENERGY EFFICIENCY Tr a n q u i l i t y ® 2 0 ( T S ) S e r i e s R e v. : 0 7 / 1 7 / 1 3 Model Nomenclature - General Overview 1 2 3 4 5 6 7 9 TS V 0 24 A G C 1 8 10 11 12 13 14 15 0 A L T S SERIES STANDARD TS = Tranquility® Single Stage S = Standard CONFIGURATION SUPPLY AIR FLOW & MOTOR CONFIGURATION V = Vertical Up H = Horizontal D = Vertical Down Option T D B S V U Y Z K N P W UNIT SIZE 006 - E,G 009 - E,G 012 - E,G 018 - E, G 024 - E, G, H, F 030 - E, G, H, F 036 - E, G, H, F 042 - G, H, F, N 048 - G, H, F, N 060 - G, H, F, N 070 - G, H, F, N Supply Configuration Motor Top TSV PSC Down TSD PSC Back TSH PSC Straight TSH PSC Top TSV PSC Hi Static PSC Hi Static TSD Down PSC Hi Static TSH Back PSC Hi Static TSH Straight Top TSV ECM ECM TSD Down ECM TSH Back ECM TSH Straight REVISION LEVEL A = 006-070 B = 018 RETURN AIR FLOW CONFIGURATION VOLTAGE L = Left Return R = Right Return G = 208-230/60/1 E = 265/60/1 H = 208-230/60/3 F = 460/60/3 N = 575/60/3 HEAT EXCHANGER OPTIONS Non Coated Air Coil Coated Air Coil Copper Cupro-Nickel Copper Cupro-Nickel C N A J Standard Motorized Valve T S U W ® E P D F ClimaDry CONTROLS C = CXM D = DXM L= CXM w/LON M = DXM w/LON N = CXM w/MPC P = DXM w/MPC A = CXM B = DXM E = CXM w/LON K = DXM w/LON R = CXM w/MPC S = DXM w/MPC } w/Disconnect WATER CIRCUIT OPTIONS 0 = None 2 = HWG (Coil Only) 5 = Internal Secondary Pump 6 = HWG (Coil Only) w/Auto Flow Regulator 2.5 GPM/Ton 7 = HWG (Coil Only) w/Auto Flow Regulator 3.0 GPM/Ton 8 = Auto Flow Regulator 2.5 GPM/Ton 9 = Auto Flow Regulator 3.0 GPM/Ton Cabinet OPTION RANGE 1 A J K 2 C L M 3 E N P 4 G R S ULTRA QUIET NO YES NO YES 1” FILTER 2” FILTER 1” FILTER 2” FILTER RAIL RAIL FRAME FRAME YES NO NO YES NO YES NO NO NO YES YES NO NO YES NO YES NO NO NO YES YES NO NO YES NO NO YES NO NO YES YES NO NO YES NO YES NO YES NO NO Note: Above model nomenclature is a general reference. Consult individual engineering guides for detailed information. ClimaDry® II Option Notes: 1. Unit must have DXM control option. 460 volt unit units require a four wire power supply with neutral. 2. ClimaDry® II may not be combined with motorized water valve, internal secondary circulating pump, or automatic flow regulator options. 3. Unit minimum entering air temperature while in the dehumidification, cooling, or continuous fan modes is 70ºF DB/61ºF WB. Operation below this minimum may result in nuisance faults. 4. A thermostat with dehumidification mode or thermostat and separate humidistat/dehumidistat is required for activation and control of ClimaDry® II. 5. Downflow and 575 volt units are not eligible for ClimaDry® II. c l i m a t e m a s t e r. c o m 3