Download PDF - Performance Waterjet
Transcript
Section 9 High Pressure Water System 9.4 Service and Maintenance Overview Never perform any type of maintenance on the high pressure water system while it is pressurized. Always turn the power off and bleed the high pressure water before servicing. Pressing the emergency stop button turns the control power off to the intensifier, and bleeds high pressure water through the dump valve. Improper assembly can lead to the premature failure of components. Maintenance procedures must be followed carefully; components must be properly cleaned prior to assembly and tightened to the correct torque specifications. Some high pressure components are not serviceable at the customer level, others require precise refinishing. KMT Waterjet Systems offers maintenance and refinishing services for these components. NOTE Refer to Section 12, Parts List for a complete listing of replacement parts and part numbers. 20480314 7-2011/Rev 02 9-6