Download MAINTENANCE INTERVALS - Safety
Transcript
SEBU7857-04 141 Maintenance Section Hydraulic System Oil - Change Clean the oil cooler and clean the radiator at the same time. Clean the oil cooler in the same manner as you clean the radiator. You can use compressed air, high pressure water, or steam to remove dust and other debris from the radiator core. However, the use of compressed air is preferred. Note: Care must be taken when you are using high pressure water. High pressure water can cause damage to the radiator. Use of a water spray nozzle on the pressure washer which will disperse the water pressure is preferred. Note: Cat HYDO Advanced 10 has a 50% increase in the standard oil drain interval for machine hydraulic systems (3000 hours versus 2000 hours) over second and third choice oils - when following the maintenance interval schedule for oil filter changes and for oil sampling that is stated in the Operation and Maintenance Manual for your particular machine. 6000 hour oil drain intervals are possible when using S·O·S Services oil analysis. Contact your Cat dealer for details. Note: At the same interval, clean the air conditioner condenser. i03210861 Hydraulic System Oil - Change SMCS Code: 5056-044 S/N: DBC1-Up Illustration 169 g01124541 NOTICE Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Hydraulic tank drain valve (1) is located on the bottom of the hydraulic tank in front of the right tractor wheel. Refer to Special Publication, NENG2500, “Caterpillar Dealer Service Tool Catalog” for tools and supplies suitable to collect and contain fluids on Caterpillar products. • The parking brake must be applied. Dispose of all fluids according to local regulations and mandates. Note: The normal hydraulic oil change interval is at every 2000 Service Hours or 1 Year. By performing S·O·S oil analysis, the hydraulic oil change interval may be extended to 4000 Service Hours or 2 Years. S·O·S oil analysis must be performed at every 500 Service Hours or 3 Months in order to extend the hydraulic oil change interval. The results from the S·O·S oil analysis will determine if the hydraulic oil change interval may be extended. If S·O·S oil analysis is not available, the hydraulic oil change interval must remain at every 2000 Service Hours or 1 Year . Refer to the Operation and Maintenance Manual, “S·O·S Information”. Note: Before you change the hydraulic tank oil, the machine must meet the following conditions: • The machine must be level. • The hydraulic oil must be warm. • The transmission control must be in NEUTRAL. • The bowl must be lowered. Illustration 170 g01124542 Hydraulic oil filler cap (3) is located on top of the hydraulic tank.