Transcript
WIRING DIAGRAMS ASPT**14**/ASUF**14** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. FL FL FL TL HTR 1 FL BK BK HTR1 FL BK FL BK 1 HTR2 RD FL BK 1 RD PU 4 M1 R RD 6 M3 4 M2 M4 5 7 BK RD RD BL M3 M4 M2 3 RD BL M1 R2 BR BK RD WH M1 YL RD M3 M2 M4 R1 6 M5 M7 M6 M8 3 RD BL R2 BR BK BK RD WH 4 5 6 7 8 YL BK 8 1 2 YL 7 RD RD 9 BL BK RD 9 9 L1 BK BL 4 5 7 BK BK RD 6 BK 8 BL PU M2 R1 WH BK RD BK BL PU BK M1 M1 R WH YL 3 BL BK 5 M2 YL TL 2 YL RD 2 3 BL RD TL HTR3 FL 1 HTR4 RD PU BK BK TL HTR2 TL HTR3 BK RD 2 TL HTR1 FL TL TL HTR2 FL TL TL HTR1 8 9 L2 L1 L2 L1 L2 L1 L2 L1 ONE (1) ELEMENT ROWS TWO (2) ELEMENT ROWS L2 L1 L2 FOUR (4) ELEMENT ROWS TH REE (3) ELEMENT ROWS NOTE: W HEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOW ER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK A "X" IN THE BOX PROVIDED ABOVE. MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. 208/240 VOLTS EQUIP MENT GROUND USE COPPER WIRE GRD SEE NOT E 2 R C G W 1 W 2 Y1 Y2 O DH 1 2 3 4 5 L1 L1 L2 PLF 1 2 3 4 5 6 7 8 9 PLM 1 2 3 4 5 6 7 8 9 BK RD BL BR WH 1 1 RD GR L2 PLF WIRING CODE 5 FACTORY W IRING HIGH VOLTAGE LOW VOLTAGE FIELD W IRING HIGH VOLTAGE LOW VOLTAGE PLF 2 EM PLM LGN PLM SEE NOTE 4 2 2 1 3 SEE NOTE 1 BR WH 1 2 3 4 24V 5 4 CR TR PLF PLM FL TL HTR ALTERNATE HEAT RELAY 1 BL TR RD WH CR BK 7 RD GR 4 1 A B RD SEE NOTE 1 BK WH C RD 1 2 3 5 24V 4 FUSE HOLDER PU 6 5 B A 4 7 240 TR R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 BL BL BL BL BL RD RD COPPER POWER SUPPLY (USE RATING PLATE) USE MIN. 75° C FIELD WIRE WH PU FUSE HOLDER OR BR YL 1 2 34 5 EM PU 4 IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. RD 2 5 GR 1 3 C LGN WH BL ALTERNATE HEAT RELAY RD BK BL NOTES: 1) RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON TERMINAL "2" FOR 280 VOLTS. 1 2 3 4 5 EM BK RD YL BL BLACK GR GREEN RED PU PURPLE YELLOW BR BROWN BLUE WH WHITE C C OMPONENT CODE EM TB R CR EBTDR EVAPORATOR MOTOR TERM INAL BOARD RELAY CONTROL RELAY ELECTR ONIC BLOWER TIME DELAY RELAY 2) SEE COMPLETE WIRING DIAGRAMS IN INSTALLATIO N INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRIN G CONNECTIONS. 3) CONFIRM SPEED TAP SELECTIO N IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT PURPLE WIRE FROM TERMINAL 4 OF CR RELAY TO APPROPRIATE TAP AT TB. 4) BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY. BL COLOR CODE CR 4 P LM TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CON NECTOR FUSE LINK THERMAL LIMIT HEAT ELEMENTS 0140A00063-A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 21