Download TECHNICAL MANU TECHNICAL MANUAL

Transcript
WIRING DIAGRAMS
ASPT**14**/ASUF**14**
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
FL
FL
FL
TL
HTR 1
FL
BK
BK
HTR1
FL
BK
FL
BK
1
HTR2
RD
FL
BK
1
RD
PU
4
M1
R
RD
6
M3
4
M2
M4
5
7
BK
RD
RD
BL
M3
M4
M2
3
RD
BL
M1
R2
BR
BK
RD
WH
M1
YL
RD
M3
M2
M4
R1
6
M5
M7
M6
M8
3
RD
BL
R2
BR
BK
BK
RD
WH
4
5
6
7
8
YL
BK
8
1
2
YL
7
RD
RD
9
BL
BK
RD
9
9
L1
BK
BL
4
5
7
BK
BK RD
6
BK
8
BL
PU
M2
R1
WH
BK
RD
BK
BL
PU
BK
M1
M1
R
WH
YL
3
BL
BK
5
M2
YL
TL
2
YL
RD
2
3
BL
RD
TL
HTR3
FL
1
HTR4
RD
PU
BK
BK
TL
HTR2
TL
HTR3
BK
RD
2
TL
HTR1
FL
TL
TL
HTR2
FL
TL
TL
HTR1
8
9
L2
L1
L2
L1
L2
L1
L2
L1
ONE (1) ELEMENT ROWS
TWO (2) ELEMENT ROWS
L2
L1 L2
FOUR (4) ELEMENT ROWS
TH REE (3) ELEMENT ROWS
NOTE: W HEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOW ER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS
UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK A "X" IN THE BOX PROVIDED ABOVE. MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK
INDICATES NO HEAT KIT INSTALLED.
208/240 VOLTS
EQUIP MENT GROUND
USE COPPER WIRE
GRD
SEE NOT E 2
R C G W 1 W 2 Y1 Y2 O DH 1 2 3 4 5
L1
L1
L2
PLF
1
2
3
4
5
6
7
8
9
PLM
1
2
3
4
5
6
7
8
9
BK
RD
BL
BR
WH
1
1
RD
GR
L2
PLF
WIRING CODE
5
FACTORY W IRING
HIGH VOLTAGE
LOW VOLTAGE
FIELD W IRING
HIGH VOLTAGE
LOW VOLTAGE
PLF 2
EM
PLM
LGN
PLM
SEE
NOTE 4
2
2
1
3
SEE NOTE 1
BR
WH
1
2
3
4
24V
5
4
CR
TR
PLF
PLM
FL
TL
HTR
ALTERNATE HEAT RELAY
1
BL
TR
RD
WH
CR
BK
7
RD
GR
4
1
A
B
RD
SEE
NOTE 1
BK
WH
C
RD
1
2
3
5
24V
4
FUSE
HOLDER
PU
6
5
B
A
4
7
240
TR
R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5
BL
BL
BL
BL
BL
RD
RD
COPPER POWER SUPPLY
(USE RATING PLATE)
USE MIN. 75° C FIELD WIRE
WH PU
FUSE
HOLDER
OR BR YL
1 2 34 5
EM
PU
4
IF REPLACEMENT OF THE ORIGINAL WIRES
SUPPLIED WITH THIS ASSEMBLY IS NECESSARY,
USE WIRE THAT CONFORMS TO THE NATIONAL
ELECTRIC CODE.
RD
2
5
GR
1
3
C LGN
WH
BL
ALTERNATE HEAT RELAY
RD BK
BL
NOTES:
1) RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON
TERMINAL "2" FOR 280 VOLTS.
1
2
3
4
5
EM
BK
RD
YL
BL
BLACK
GR GREEN
RED
PU PURPLE
YELLOW BR BROWN
BLUE
WH WHITE
C
C OMPONENT CODE
EM
TB
R
CR
EBTDR
EVAPORATOR MOTOR
TERM INAL BOARD
RELAY
CONTROL RELAY
ELECTR ONIC BLOWER TIME
DELAY RELAY
2) SEE COMPLETE WIRING DIAGRAMS IN INSTALLATIO N INSTRUCTIONS FOR
PROPER LOW VOLTAGE WIRIN G CONNECTIONS.
3) CONFIRM SPEED TAP SELECTIO N IS APPROPRIATE FOR APPLICATION. IF
SPEED TAP NEEDS TO BE CHANGED, CONNECT PURPLE WIRE FROM TERMINAL 4 OF CR
RELAY TO APPROPRIATE TAP AT TB.
4) BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY.
BL
COLOR CODE
CR
4 P LM
TRANSFORMER
FEMALE PLUG CONNECTOR
MALE PLUG CON NECTOR
FUSE LINK
THERMAL LIMIT
HEAT ELEMENTS
0140A00063-A
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
21