Transcript
Standard Bus Procurement Guidelines 5.4.4.4.6 Fastening Interior panels shall be attached so that there are no exposed unfinished or rough edges or rough surfaces. Panels and fasteners shall not be easily removable by passengers. Interior trim fasteners, where required, shall be rivets or cross-recessed head screws. 5.4.4.4.7 Insulation Any insulation material used between the inner and outer panels shall be sealed or self-sealing to minimize entry and/or retention of moisture. Insulation properties shall be unimpaired during the service life of the bus. Any insulation material used inside the engine compartment shall not absorb or retain oils or water and shall be designed to prevent casual damage that may occur during maintenance operations. All insulation materials shall comply with the Recommended Fire Safety Practices defined in FTA Docket 90, dated October 20,1993. The combination of inner and outer panels on the sides, roof, wheelwells and ends of the bus, and any material used between these panels shall provide a thermal insulation sufficient to meet the interior temperature requirements of Part 5: Technical Specifications. The bus body shall be thoroughly sealed so that the operator or passengers cannot feel drafts during normal operation s with the passenger doors closed. 5.4.4.5 FLOOR COVERING The floor covering shall have a non-skid walking surface that remains effective in all weather conditions and complies with all ADA requirements. The floor covering, as well as transitions of flooring material to the main floor and to the stepwell area, shall be smooth and present no tripping hazards. The standee line shall be at least 2 inches wide and shall extend across the bus aisle. This line shall be the same color as the edge of the steps. Color shall be consistent throughout the floor covering. Color and material of the floor covering is defined in attachment to Part 5: Technical Specifications. The floor in the operator's compartment shall be easily cleaned and shall be arranged to minimize debris accumulation. A one-piece center strip shall extend from the vertical wall of the rear settee between the aisle sides of transverse seats to the standee line. The covering between the center strip and the wheel housings may be separate pieces. At the rear door, however, a separate strip as wide as the door shall extend from the center strip to the top step. The floor under the seats shall be covered with smooth surface flooring material. The floor covering shall closely fit the sidewall cove or extend to the top of the cove. Technical Specifications 48 1/22/08