INSTALLATION
Heater Block Set-up
The Coder is supplied with the Heater Block configured to accept either 30mm wide Type holders (used by the Compact
205 series) or 35mm wide Type holders (to make use of the 50/30 print area). The configuration for 30mm wide Type
holders is shown below:
Configuration for 35mm wide Type holders
To configure the Heater Block to accept 35mm wide Type holders make the following changes:
1.
Ensure the Coder is not connected to the Power and Compressed Air supplies.
WARNING
Heating block cool down
If the coder has recently been in use allow the heater block to cool before continuing
38
2.
Remove the Magazine and type holder from the Coder, then remove the Heater Block Guard
3.
Carefully remove the clip (1) retaining the long detent (2).
4.
Withdraw the long detent (2).
5.
Undo and remove the 2 screws (3).
6.
Remove the Heater Block Insert (4).
7.
Extract the clip and short detent (5).
8.
Insert the short detent (5) into the Heater Block in place of the long detent and retain using the clip.
S-Compact 50/30
M00201100EN0313