NOTE : THE FOOD COMPARTMENT CONTROL USED WITH ADC I USED 3 CONTACT POINTS. THE FOOD COMPARTMENT CONTROL USED WITH ADC II WILL ONLY NEED 2. IF THE PRODUCT HAS A 3 TERMINAL CONTROL OR IF YOU INSTALL A 3 WIRE CONTROL, CONNECT THE BLACK WIRE TO TERMINAL NUMBER 2 AND THE PURPLE WITH WHITE TRACER WILL CONNECT TO TERMINAL 3. TERMINAL NUMBER 1 IS NOT USED. FIGURE 4 The replacement of the cold controls and damper are the same on both control boxes. The ADC II is mounted inside a box. To replace, use a small screwdriver and release the tabs in the front of the control box. (See Figure 5.) This will allow you to remove the cover and get to the board. (See Figure 6.) Now lift the ADC out of the housing and disconnect the plug. (See Figure 7.) RELEASE TABS LIFT OFF COVER FIGURE 5 FIGURE 6 LIFT BOARD OUT AND DISCONNECT FIGURE 7 16