Download VERTICAL MAST
Transcript
Section 4 - Troubleshooting Information Service and Maintenance Electrical System (Continued) 5. Loose or broken wire #19A from control box connector pin #C4 to limit switch LS4. -- Check continuity. Replace if defective. 6. Loose or broken wire #19B from limit switch LS4 to control box connector pin #C4. -- Check continuity. Replace if defective. 7. Defective limit switch LS4. -- Check limit switch. Replace if defective. 8. Loose or broken wire #19B in mast control cable or its connectors. -- Check for continuity between base connector X2 pin #6 and platform connector X1 pin #C9 on cable. Check for loose or corroded connections on cable connectors. Replace if wire is defective. 9. Loose or broken wire #19B from diagnostic switch S5 to mast control cable. -- Check continuity. Replace if defective. 10. Loose or broken wire #19B from diagnostic switch S5 to motor controller. -- Check continuity. Replace if defective. 11. Defective resistor RST6. (With joystick fully stroked) -- Check resistor and make sure it is secure. Replace if defective. 12. Loose or broken B- cable from batteries to B- lug on motor controller. -- Check continuity. Replace if defective. 13. Loose or broken B+ cable from main battery disconnect switch S1 to motor contactor C1. -- Check continuity. Replace if defective. 14. Loose or broken B+ cable from motor contactor C1 to motor DCM1. -- Check continuity. Replace if defective. 15. Loose or broken B+ cable from motor DCM1 to B+ lug on motor controller. -- Check continuity. Replace if defective. 16. Loose or broken B- cable from motor DCM1 to M- lug on motor controller. -- Check continuity. Replace if defective. 17. Defective motor controller. -- Check motor controller input and output voltage. Replace if defective. 18. Defective motor DCM1. -- Check motor for operation with 24 volt supply. Replace if defective. 4.1-3 All Controls Inoperative From Base Control Console 1. Loose or broken wire #07A from base terminal block to base key switch S10. -- Check continuity. Replace if defective. 2. Open or defective base key switch S10. -- Close switch. Replace if defective. 3. Loose or broken wire #10E from base key switch S10 to base up/down switch S2. -- Check continuity. Replace if defective. 4.1-4 No Up Function from Base Control Console 1. Defective up/down switch S2. -- Check switch. Replace if defective. 2. Loose or broken wire #14B from up/down switch S2 to base terminal block. -- Check continuity. Replace if defective. 3. Open diode D14B-1. -- Check diode. Replace if defective. 4. Open diode D14B. -- Check diode. Replace if defective. 5. Loose or broken wire #14 on base terminal block between diode D14B and diode D14. -- Check continuity. Replace if defective. Vertical Mast Series Model SJ12 155185 Page 69