Download VERTICAL MAST

Transcript
Section 4 - Troubleshooting Information
Service and Maintenance
Electrical System (Continued)
5. Loose or broken wire #19A from control box connector pin #C4 to limit switch LS4.
-- Check continuity. Replace if defective.
6. Loose or broken wire #19B from limit switch LS4 to control box connector pin #C4.
-- Check continuity. Replace if defective.
7. Defective limit switch LS4.
-- Check limit switch. Replace if defective.
8. Loose or broken wire #19B in mast control cable or its connectors.
-- Check for continuity between base connector X2 pin #6 and platform connector X1 pin #C9 on
cable. Check for loose or corroded connections on cable connectors. Replace if wire is defective.
9. Loose or broken wire #19B from diagnostic switch S5 to mast control cable.
-- Check continuity. Replace if defective.
10. Loose or broken wire #19B from diagnostic switch S5 to motor controller.
-- Check continuity. Replace if defective.
11. Defective resistor RST6. (With joystick fully stroked)
-- Check resistor and make sure it is secure. Replace if defective.
12. Loose or broken B- cable from batteries to B- lug on motor controller.
-- Check continuity. Replace if defective.
13. Loose or broken B+ cable from main battery disconnect switch S1 to motor contactor C1.
-- Check continuity. Replace if defective.
14. Loose or broken B+ cable from motor contactor C1 to motor DCM1.
-- Check continuity. Replace if defective.
15. Loose or broken B+ cable from motor DCM1 to B+ lug on motor controller.
-- Check continuity. Replace if defective.
16. Loose or broken B- cable from motor DCM1 to M- lug on motor controller.
-- Check continuity. Replace if defective.
17. Defective motor controller.
-- Check motor controller input and output voltage. Replace if defective.
18. Defective motor DCM1.
-- Check motor for operation with 24 volt supply. Replace if defective.
4.1-3 All Controls Inoperative From Base Control Console
1. Loose or broken wire #07A from base terminal block to base key switch S10.
-- Check continuity. Replace if defective.
2. Open or defective base key switch S10.
-- Close switch. Replace if defective.
3. Loose or broken wire #10E from base key switch S10 to base up/down switch S2.
-- Check continuity. Replace if defective.
4.1-4 No Up Function from Base Control Console
1. Defective up/down switch S2.
-- Check switch. Replace if defective.
2. Loose or broken wire #14B from up/down switch S2 to base terminal block.
-- Check continuity. Replace if defective.
3. Open diode D14B-1.
-- Check diode. Replace if defective.
4. Open diode D14B.
-- Check diode. Replace if defective.
5. Loose or broken wire #14 on base terminal block between diode D14B and diode D14.
-- Check continuity. Replace if defective.
Vertical Mast Series
Model SJ12
155185
Page 69