Download 5 ERROR CODES
Transcript
6 Service Manual DS 160 5.3.2 Error Codes for the Analog Inputs If it exceeds these limits, the following errors are triggered: (NOTE: the upper limit follows the lower limit error, i.e. 11 and 21, 12 and 22, 13 and 23…) Error Code Error Fallen below limit E11 for the measuring channel "Length telescopic boom". E21 E12 E22 Cause Elimination • Length sensor potentiometer defective. • Replace length sensor potentiometer. • Electronic board in the measuring channel defective. Upper limit value for • Length sensor measuring channel potentiometer defective. "length telescopic boom" exceeded. • Electronic part in the measuring channel defective. Fallen below the • Cable between the lower limit value in central unit and pressure the measuring transducers defective or channel "pressure water inside the plugs piston side" Upper limit value in measuring channel "pressure piston side" has been exceeded © PAT Rev. C 06/14/02 • Replace LMI board. • Replace length sensor potentiometer. • Replace LMI board. • Check cable as well as plugs, replace, if need be. • Pressure transducer is • Replace pressure defective. transducer • Electronic component in • Replace LMI main board the measuring channel is or processor board. defective. • refer to E12 • refer to E12 190142_D