Download AVR347 - Quality & Performance
Transcript
harman/kardon AVR347 AMPLIFIER SECTION BIAS ADJUSTMENT Measurement condition .No input signal or volume position is minimum. Standard value .Ideal current = 48mA (± 5%) .Ideal DC Voltage = 25.92mV (± 5%) DC EVM + - CN66 VR31 CUP11911* (MAIN PCB) CN61 VR32 CN64 VR33 CN63 VR34 CN65 VR35 CN62 VR36 CN67 VR37 DC VOLTMETER ; Connect to CN66(SL),CN61(CEN),CN64(SR),CN63(FL),CN65(SBL),CN62(FR),CN67(SBR) NO. 1 2 3 4 5 6 7 Channel Front Left Front Right Center Surround Left Surround Right Surround Back Left Surround Back Right Adjust for 25.92mV (± 5%) 25.92mV (± 5%) 25.92mV (± 5%) 25.92mV (± 5%) 25.92mV (± 5%) 25.92mV (± 5%) 25.92mV (± 5%) 50 Adjustment CN63 CN62 CN61 CN66 CN64 CN65 CN67