Download INSTALLATION AND SERVICE MANUAL
Transcript
Installation and Service Manual The combination gas valves have an integral vent limiting device and does not require venting to atmosphere outside the building. The unit will not operate properly if the reference hose is removed or a vent to atmosphere is installed. COMBINATION VALVE DOWNSTREAM TEST VALVE Optional gas controls may require routing of bleeds and vents to the atmosphere outside the building when required by local codes. Connecting Gas Piping to Unit TO BURNERS ADDITIONAL VALVES BASED ON UNIT INPUTS All gas connections must be made with pipe joint compound Figure 19 - Gas Train Drawing resistant to the action of liquefied petroleum (L.P.) and TABLE-F natural gases. All piping must comply with local codes and Suggested Gas Pipe Size for Single Unit Installations ordinances. Piping installations must comply with approved Btu/hr Distance From Meter (in feet) standards and practices. 0-50 51-100 101-200 201-300 301-500 1. Make sure gas line is a separate line direct from the meter Input unless the existing gas line is of sufficient capacity. Verify 495,000 pipe size with your gas supplier. 2. Use new, properly threaded black iron pipe free from 645,000 chips. If you use tubing, make sure the ends are square, deburred and clean. Make all tubing bends smooth and 745,000 without deformation. Avoid flexible gas connections. Internal diameter of flexible lines may not provide unit 985,000 with proper volume of gas. 3. Install a manual main gas shutoff valve at the unit’s gas 1,255,000 inlet, outside of the unit. 1 1/4" 1 1/4" 1 1/2" 2" 2" 1 1/4" 1 1/2" 2" 2" 2 1/2" 1 1/2" 2" 2" 2 1/2" 2 1/2" 2" 2" 2 1/2" 2 1/2" 3" 2" 2 1/2" 2 1/2" 3" 3" 2 1/2" 3" 3" 3 1/2" 3" 3" 3 1/2" 3 1/2" 3" 3" 3 1/2" 4" 1,435,000 2 1/2" 4. Run pipe or tubing to the unit’s gas inlet. If you use tubing, obtain a tube to pipe coupling to connect the tubing to the 1,795,000 2 1/2" unit’s gas inlet. 5. Install a sediment trap in the supply line to the unit’s gas 2,065,000 2 1/2" inlet (see Figure 17). For each elbow or tee, add equivalent straight pipe to total length from table below. 6. Apply a moderate amount of good quality pipe compound (do not use Teflon tape) to pipe only, leaving two end threads bare. Gas Train and Controls Note: The gas train and controls assembly provided on this unit have been tested under the applicable American National Standard to meet minimum safety and performance criteria such as safe lighting, combustion and safety shutdown operation. 7. Remove seal over gas inlet to unit. 8. Connect gas pipe to inlet of unit. Use wrench to support gas manifold on the unit. 9. For L.P. gas, consult your L.P. gas supplier for expert installation. Figure 19 shows a typical gas train. 10. Ensure that all air is properly bled from the gas line before starting the ignition sequence. Start up without properly bleeding air from the gas line may require multiple reset functions of the ignition control module to achieve proper ignition. TABLE-G Fittings to Equivalent Straight Pipe Diameter Pipe (inches) 3/4 1 1 1/4 1 1/2 2 3 4 5 Equivalent Length of Straight Pipe (feet) WARNING: Do not have any open flame in proximity to the gas line when bleeding air from the gas line. Gas may be present. 2 2 3 4 TABLE-F 17 5 10 14 20