Download INSTALLATION AND SERVICE MANUAL

Transcript
Installation and
Service Manual
The combination gas valves have an integral vent limiting
device and does not require venting to atmosphere outside the
building. The unit will not operate properly if the reference
hose is removed or a vent to atmosphere is installed.
COMBINATION VALVE
DOWNSTREAM
TEST VALVE
Optional gas controls may require routing of bleeds and vents
to the atmosphere outside the building when required by local
codes.
Connecting Gas Piping to Unit
TO BURNERS
ADDITIONAL VALVES BASED
ON UNIT INPUTS
All gas connections must be made with pipe joint compound Figure 19 - Gas Train Drawing
resistant to the action of liquefied petroleum (L.P.) and
TABLE-F
natural gases. All piping must comply with local codes and
Suggested Gas Pipe Size for Single Unit Installations
ordinances. Piping installations must comply with approved
Btu/hr
Distance From Meter (in feet)
standards and practices.
0-50 51-100 101-200 201-300 301-500
1. Make sure gas line is a separate line direct from the meter Input
unless the existing gas line is of sufficient capacity. Verify
495,000
pipe size with your gas supplier.
2. Use new, properly threaded black iron pipe free from 645,000
chips. If you use tubing, make sure the ends are square,
deburred and clean. Make all tubing bends smooth and 745,000
without deformation. Avoid flexible gas connections.
Internal diameter of flexible lines may not provide unit 985,000
with proper volume of gas.
3. Install a manual main gas shutoff valve at the unit’s gas 1,255,000
inlet, outside of the unit.
1 1/4"
1 1/4"
1 1/2"
2"
2"
1 1/4"
1 1/2"
2"
2"
2 1/2"
1 1/2"
2"
2"
2 1/2"
2 1/2"
2"
2"
2 1/2"
2 1/2"
3"
2"
2 1/2"
2 1/2"
3"
3"
2 1/2"
3"
3"
3 1/2"
3"
3"
3 1/2"
3 1/2"
3"
3"
3 1/2"
4"
1,435,000 2 1/2"
4. Run pipe or tubing to the unit’s gas inlet. If you use tubing,
obtain a tube to pipe coupling to connect the tubing to the 1,795,000 2 1/2"
unit’s gas inlet.
5. Install a sediment trap in the supply line to the unit’s gas 2,065,000 2 1/2"
inlet (see Figure 17).
For each elbow or tee, add equivalent straight pipe to total length from table below.
6. Apply a moderate amount of good quality pipe compound
(do not use Teflon tape) to pipe only, leaving two end
threads bare.
Gas Train and Controls
Note: The gas train and controls assembly provided on
this unit have been tested under the applicable American
National Standard to meet minimum safety and performance
criteria such as safe lighting, combustion and safety shutdown
operation.
7. Remove seal over gas inlet to unit.
8. Connect gas pipe to inlet of unit. Use wrench to support
gas manifold on the unit.
9. For L.P. gas, consult your L.P. gas supplier for expert
installation.
Figure 19 shows a typical gas train.
10. Ensure that all air is properly bled from the gas line before
starting the ignition sequence. Start up without properly
bleeding air from the gas line may require multiple reset
functions of the ignition control module to achieve proper
ignition.
TABLE-G
Fittings to Equivalent Straight Pipe
Diameter Pipe (inches)
3/4
1
1 1/4
1 1/2
2
3
4
5
Equivalent Length of Straight Pipe (feet)
WARNING: Do not have any open flame in
proximity to the gas line when bleeding air from
the gas line. Gas may be present.
2
2
3
4
TABLE-F
17
5
10
14
20