Download Compact75E_UIS
Transcript
13 Fault Finding 7402 Check appliance installation and that it is mechanically correct. YES Check filters are clean and allow adequate water flow. YES NO Check fuses and power supply. Is mains L.E.D. illuminated. YES Open a tap to create demand. YES NO If lockout L.E.D. is illuminated, press reset. YES A NO Demand L.E.D. illuminated. Check flow switch operation. YES B NO Pump starts. Check the pump is not mechanically stuck. Check 230V supply to pump. YES C NO Fan starts. Check air pressure switch operation. Check 230V supply to fan. Check thermistor. Unplug fan and check coil resistance. YES D NO Start spark. Check spark electrodes and cables. Check primary circuit overheat continuity. Check air pressure switch status and operation. YES E Gas control valve opens at ignition rate (5-6 mbar). NO Check gas control valve cables. Check gas control valve voltage. Check venturi and connecting tubes. YES F Burner pressure increases to full rate. NO Goes to lockout. Check sensing electrode and cables. Check burner for cross lighting. YES G Turn control thermostat or flow rate down to induce modulation. NO Is heating circuit getting hot. Check 3 way valve operation. YES Manually push brass splindle in diverter valve. Does domestic hot water get hot when pushed in and central heating water get hot when released. Domestic hot water operates. YES Unclip motor. Turn domestic hot water Off and On. Does pin move in and out. Switch to central heating demand. YES NO Demand L.E.D. illuminates. Replace motor. If domestic hot water demand is still illuminated. Faulty domestic hot water switch. YES Follow B-G. YES Correct operation. Diagram 13.3 221895A 30