Download Jbl-PB10 actsub

Transcript
PB10
PB10 Testing Procedure (Cont.) (Revision 2 Only)
- Voltage measurements
U2(1)
U2(14)
U2(8)
U3(7)
OP AMP
U3(1)
133.6mV
200.2mV
245.9mV
314.8mV
314.9mV
U3(14)
U3(8)
U5(7)
U5(1)
SPEAKER
O/P
350mV
1.67V
1.452V
2.098V
15.3V
2. High Level Input Sensitivity
-Set up
Turn level, X’OVER FREQ POT Fully CW and LFE switch off
Set Generator at 1.15V@50Hz
Signal to High level input
-Voltage measurements 15.3V at speaker output
3. Low-Pass
-Set up
Set Generator at 100 mV@100Hz
Signal to Line level input
Measure voltage at S+ speaker output
-Voltage measurement
X’OVER FREQ. Setting
CW
CCW
Output
10.72V
2.165V
4. LFE
-Set up
Set Generator at 100mV@200Hz
Signal to Line level input
Measure voltage at S+ speaker output
LFE switch Setting
Normal
LFE
Output
2.9V
7.62V
See flow chart next page for diagnostics.
27