Download Technical Service Manual Version One
Transcript
FG Series wind pipe blowing air-conditioning unit Section One A series small ducted type unit Overview of chapter one 1.1, Product summary The ducted type unit means that the outdoor unit and the indoor unit are connected by a copper pipe and the air-supply pipe leads to each room from the indoor. That is why it is called the ducted pipe unit. The detailed working method is that: the indoor heat exchangers gather in an indoor unit, the cool air produced by the indoor unit is sent to each room from the system air duct, then is sent back to the indoor unit via the air duct, after it is cooled and mixed with some fresh air, it is sent out again. This is a central air conditioner with the complete air system. Gree’s A series of air conditioner unit with the air supplied by the small air duct combines the advantages of the central air conditioner which are being comfortable and top-grade and the advantages of the small type of separated home air conditioner which are being convenient and flexible in installation, etc. It is highly efficient, energy-saving with a long air supply distance and good indoor air quality. It is reliable in operation and convenient in usage and is widely applied to various small supermarkets, chain stores, families with multiple living rooms, hotels, restaurants, offices, meeting rooms and villa families. The existing models of the A series of small ducted type units are shown in Table 1.1-1. Table 1.1-1 Cooling only Item Multi-excess pressure unit Common excess pressure unit FG2.6H/A FG5H/A FG7.5H/A FG10H/A FG3.5H/A FG6.5H/A FGD10H/A FG12H/A FG6.5/A FG10/A FG7.5/A FG12/A 1.1, Expression method and example of unit model 1.2.1 Product expression FG ( Heat pump FGR2.6H/A FGR3.5H/A FGR5H/A FGR6.5H/A FGR7.5H/A FGR10H/A FGRD10H/A FGR12H/A FGR6.5/A FGR7.5/A FGR10/A FGR12/A /A Design No.: it stands for A series Unit type: O is for outdoor unit; I is for indoor unit. Frequency conversion system: P is for the frequency conversion system, the fixed frequency system is not expressed Excess pressure type: H stands for the multi-excess pressure, the common excess pressure super-thin type is not expressed Cooling capacity: Number×kW Power supply type: D is for the single-phase, the three phase is not expressed. Air conditioner type: R is for heat pump units; the cooling only units are not expressed. Product type: For the FG Series Ducted Air-conditioning Units. 1.2.2 Example FGRD10H/A: Referring to the one-way-electricity, multi-excess-pressure ducted air-conditioning (heat pump) unit with a nominal cooling capacity of 10kW. FG6.5/A: Referring to the cooling-only, common-excess-pressure ducted air-conditioning unit with a nominal cooling capacity of 6.5kW. -4-