Download T400A/W, MCD400A/W, R400A/W, MFD400A/W, D400A/W Ice

Transcript
Water-cooled ice machine capacity/24 hrs.
Air-cooled ice machine capacity/24 hrs.
Performance with new RG Group 1/2 ton coil
(Note: Data expressed in lbs/hr and kg/hr)
F
C
50
10
60
16
70
21
80
27
90
32
60
16
510
232
482
219
454
206
424
193
394
179
70
21
454
206
435
198
417
190
385
175
354
161
Ambient Air Temperature ˚F/˚C
80
27
397
180
389
177
380
173
347
158
313
142
90
32
335
152
329
150
323
147
297
135
270
123
100
38
273
124
270
123
266
121
247
112
227
103
lbs.
kg.
lbs.
kg.
lbs.
kg.
lbs.
kg.
lbs.
kg.
Inlet Water Temperature ˚F/˚C
Inlet Water Temperature ˚F/˚C
Ambient Air Temperature ˚F/˚C
F
C
50
10
60
16
70
21
80
27
90
32
60
16
451
204
423
192
394
179
371
168
352
160
70
21
447
202
413
187
390
177
361
163
342
155
80
27
442
200
409
185
380
172
352
160
333
151
90
32
437
199
399
181
371
168
342
155
323
146
100
38
428
194
394
179
361
163
333
151
309
140
lbs.
kg.
lbs.
kg.
lbs.
kg.
lbs.
kg.
lbs.
kg.
Note: Nominal values – actual production may vary by ± 10%
Gearmotor data
Gearmotor current
Locked rotor amps
2.25A (nominal)
14A
Electrical control system operation
MCD400A/WBT, MCD400A/WHT and MFD400A/WBT wiring diagram
Follett ice machines used on top of an ice storage bin have a slightly different circuitry. A diagram for these ice
machines is shown below. The operational and diagnostic stages for these ice machines will be otherwise the
same as the following stages 1 - 10.
INPUT
POWER
W
B
WATER
SENSOR
G
GRD
PWR
GRD
BLACK
M
WHITE
DR
L1
L2
C
CONTROL
BOARD
L2
L2
L2
R
C
ORANGE
S
RED
M
1
S
L BLACK
BLACK
BLACK
HIGH PRESSURE
SAFETY SWITCH
BLACK
4
BLUE
WHITE
START
RELAY
GEAR MOTOR
2
BLACK
START
3
YELLOW
RUN
START CAP.
RED
BISON GEARMOTOR
T.O.L.
GEAR MOTOR
OR
LINIX GEARMOTOR
START
RUN
COMPRESSOR
FAN
DRIVE
BLACK
T.O.L.
BLACK
T.O.L.
21
24V
COMMON
LINE VAC
BLACK
60M
BIN SIGNAL
FROM DISPENSER
JUNCTION BOX
2ND
L2
RED
COMPRESSOR
20M
WTR
B-T
B-E
RED
FAN
L1
WHITE
WHITE
BIN T-STAT
RESET
RED
RED
COMPRESSOR
SWITCH
WHITE
BLACK