IBS6 MILK SYSTEM CLEANING INSTRUCTIONS
Cleaning Kit #98552
■ USE HOT WATER dispensed from the machine.
■ DO NOT USE COLD WATER, cleaner is not effective in cold water.
■ Use gloves and eye protection when cleaning machine.
■ Powder contains chlorine. Solution may bleach/stain countertop or clothing.
USE HOT WATER
FROM MACHINE
VEND
CLEAN
CLEAN
5 sec.
SERVICE
SWITCH
Brew
Milk
CLEAN
PROGRAM
1
• Use the provided gloves
and appropriate eye protection
while cleaning the machine.
• Open the menu board.
Press the button to open the
touch pad panel.
2
• Push the service switch
to the “CLEAN” position.
• Press and HOLD CLEAN
button until tone stops, approx 5
seconds. Select “MILK” by
pressing the right
button.
7
8
9
3
4
5
• Use the cups provided
with cleaning kit. As directed,
fill the 3 cups with hot water
dispensed from the machine.
d r
Re ane
e
Cl #2
n
ee r
Gr eane
Cl #1
#1
#2
6
• When display changes
to “INSERT CLEANER #2,”
remove the first cup and replace
it with the cup containing
Cleaner #2.
Press CLEAN button.
• When the display changes
to “INSERT FRESH WATER,”
remove the empty cup and
replace it with the cup
containing plain hot water.
Press CLEAN button.
10
• Clean interior of
refrigeration unit. Remove and
clean trays, and wipe down
tubing with a sanitized* towel.
Reinstall trays.
VEND
CLEAN
• Place both milk tubes
• Stir and dissolve the
into the cup with Cleaner #1.
Cleaner #1 packet contents into
the first cup. Stir and dissolve the Press CLEAN button.
Cleaner #2 packet contents into
the second cup.
Nothing is added to the third cup –
it remains plain hot water.
SERVICE
SWITCH
11
• Using a clean cloth,
re-insert milk tubes into milk
containers and place in
refrigerator.
12
• Use a clean towel
moistened with sanitizer* to
clean product outlets.
13
• Press the service
switch to the “VEND” position.
Secure cleaning materials and
close all doors. The milk system
cleaning process is now complete.
Caution!
■ Do not mix cleaning solutions 1 and 2 together.
■ Be certain to perform the daily cleaning to maintain machine warranty.
■ Keep out of the reach of children.
■ Read and observe all safety precautions listed on packaging.
* Use a sanitizer approved by State and Local Health Department regulations.
Concordia Coffee Systems
2900-297 Rev. B
IBS6 BREW SYSTEM CLEANING INSTRUCTIONS
■ Perform once a day.
■ Use gloves and eye protection when cleaning machine.
VEND
CLEAN
CLEAN
5 sec.
“Insert Tablet”
Brew
Milk
CLEAN
SERVICE
SWITCH
CLEAN
PROGRAM
PROGRAM
1
• Use the provided gloves
and appropriate eye protection
while cleaning the machine.
2
• Open the menu board.
Press the button to open the
touch pad panel.
3
4
• Push the service switch
to the “CLEAN” position.
• Press and HOLD CLEAN
button for 5 seconds until tone
stops. Select “BREW” by pressing
left
button.
DO NOT DO ANYTHING UNTIL
THE SCREEN INSTRUCTS
YOU TO.
8
9
5
• PLEASE WAIT until the
screen says “INSERT TABLE”.
Brew Clean Cycle
Cleaning
Please Wait
CLEAN
PROGRAM
6
• Place one Cleaning
Tablet in the brew chamber.
DO NOT mistakenly place the
tablet in the grounds chute or
coffee funnel.
7
• Press CLEAN button.
Cycle will last approx.
3 minutes.
1 Select your drink
2 Select your flavor
• After the cycle has
stopped, use your brush to
sweep away any loose grounds.
Brush loose coffee grounds
into the chute.
• When the brew cycle
is finished, open the front
doors of machine, clean the drain
tray and grate. Remove and
empty the grounds bin, and
replace it in the machine.
10
• Use a clean towel
moistened with sanitizer* to
clean product outlets.
3 Select your options
VEND
CLEAN
4 Make your drink
SERVICE
SWITCH
12
11
• Clean the machine
• Press the service
exterior. Restock all items.
switch to the “VEND” position.
Secure cleaning materials and
close all doors. The brew system
cleaning process is now complete.
Hot Liquids
Hot Surface
Caution!
* Use a sanitizer approved by Local Health Department regulations.
Concordia Coffee Systems
2900-297 Rev. B