Download Cleaning Card - Concordia Beverage Systems
Transcript
IBS6 MILK SYSTEM CLEANING INSTRUCTIONS Cleaning Kit #98552 ■ USE HOT WATER dispensed from the machine. ■ DO NOT USE COLD WATER, cleaner is not effective in cold water. ■ Use gloves and eye protection when cleaning machine. ■ Powder contains chlorine. Solution may bleach/stain countertop or clothing. USE HOT WATER FROM MACHINE VEND CLEAN CLEAN 5 sec. SERVICE SWITCH Brew Milk CLEAN PROGRAM 1 • Use the provided gloves and appropriate eye protection while cleaning the machine. • Open the menu board. Press the button to open the touch pad panel. 2 • Push the service switch to the “CLEAN” position. • Press and HOLD CLEAN button until tone stops, approx 5 seconds. Select “MILK” by pressing the right button. 7 8 9 3 4 5 • Use the cups provided with cleaning kit. As directed, fill the 3 cups with hot water dispensed from the machine. d r Re ane e Cl #2 n ee r Gr eane Cl #1 #1 #2 6 • When display changes to “INSERT CLEANER #2,” remove the first cup and replace it with the cup containing Cleaner #2. Press CLEAN button. • When the display changes to “INSERT FRESH WATER,” remove the empty cup and replace it with the cup containing plain hot water. Press CLEAN button. 10 • Clean interior of refrigeration unit. Remove and clean trays, and wipe down tubing with a sanitized* towel. Reinstall trays. VEND CLEAN • Place both milk tubes • Stir and dissolve the into the cup with Cleaner #1. Cleaner #1 packet contents into the first cup. Stir and dissolve the Press CLEAN button. Cleaner #2 packet contents into the second cup. Nothing is added to the third cup – it remains plain hot water. SERVICE SWITCH 11 • Using a clean cloth, re-insert milk tubes into milk containers and place in refrigerator. 12 • Use a clean towel moistened with sanitizer* to clean product outlets. 13 • Press the service switch to the “VEND” position. Secure cleaning materials and close all doors. The milk system cleaning process is now complete. Caution! ■ Do not mix cleaning solutions 1 and 2 together. ■ Be certain to perform the daily cleaning to maintain machine warranty. ■ Keep out of the reach of children. ■ Read and observe all safety precautions listed on packaging. * Use a sanitizer approved by State and Local Health Department regulations. Concordia Coffee Systems 2900-297 Rev. B IBS6 BREW SYSTEM CLEANING INSTRUCTIONS ■ Perform once a day. ■ Use gloves and eye protection when cleaning machine. VEND CLEAN CLEAN 5 sec. “Insert Tablet” Brew Milk CLEAN SERVICE SWITCH CLEAN PROGRAM PROGRAM 1 • Use the provided gloves and appropriate eye protection while cleaning the machine. 2 • Open the menu board. Press the button to open the touch pad panel. 3 4 • Push the service switch to the “CLEAN” position. • Press and HOLD CLEAN button for 5 seconds until tone stops. Select “BREW” by pressing left button. DO NOT DO ANYTHING UNTIL THE SCREEN INSTRUCTS YOU TO. 8 9 5 • PLEASE WAIT until the screen says “INSERT TABLE”. Brew Clean Cycle Cleaning Please Wait CLEAN PROGRAM 6 • Place one Cleaning Tablet in the brew chamber. DO NOT mistakenly place the tablet in the grounds chute or coffee funnel. 7 • Press CLEAN button. Cycle will last approx. 3 minutes. 1 Select your drink 2 Select your flavor • After the cycle has stopped, use your brush to sweep away any loose grounds. Brush loose coffee grounds into the chute. • When the brew cycle is finished, open the front doors of machine, clean the drain tray and grate. Remove and empty the grounds bin, and replace it in the machine. 10 • Use a clean towel moistened with sanitizer* to clean product outlets. 3 Select your options VEND CLEAN 4 Make your drink SERVICE SWITCH 12 11 • Clean the machine • Press the service exterior. Restock all items. switch to the “VEND” position. Secure cleaning materials and close all doors. The brew system cleaning process is now complete. Hot Liquids Hot Surface Caution! * Use a sanitizer approved by Local Health Department regulations. Concordia Coffee Systems 2900-297 Rev. B