6-2 TSD AND OLP
Normal operation of
compressor is
impossible or poor.
Separate TSD-Starter
from compressor and
measure resistance
between No. 5 and 6
of PTC-Starter with a
tester.
(Figure 19)
Observation value is
115V/60Hz : 6.8Ω±30%
The resistance value
is 0Ω (short) or
∞ (open).
Shows continuity
Separate OLP from
compressor and check
resistance value
between two terminals
of OLP with a tester.
(Figure 20)
Open
Check another
electric component.
Replace OLP.
RoHS
EECON JLLE
TSD- 115/127V
R
- 60Hz - Y
513604000
17/JUL
/06
01112
000000007Z
1234567891
Figure 19
- 21 -
Figure 20
Replace TSDStarter.