2-9. Micom Problems Symptom Causes Checks Measures Bad PCB All display Bad connection Bad connector Visual check on connector Reconnect electric power. LCD are off. between Main PCB connection from main connection. connector. and display circuit. PCB to display PCB. Remarks Defective PCB PCB transformer Check resistance of PCB Replace PCB Applicable to transformer. winding is cut. transformer input and output transformer or PCB. model without PCB transformer terminals with a tester. temperature fuse is (If resistance is infinity, trans burnt out. winding is cut). DefectivePCB electric Defective regulator IC Check voltage at input/output circuit parts. (7812, 7805). terminals. dispenser. Replace regulator. Refer to electric circuit in circuit explanation. - 69 - PCB electric terminal Check fuse in PCB electric fuse is burnt out. terminal with a tester. STR Parts are Check if STR No. 2 and 3 pins damaged. are cut when power is off. Replace PCB fuse. Replace parts. Applicable to model with dispenser. Abnormal Bad connection Lead Wire connecting Check Lead Wire terminals Reconnect Lead display LCD between Main PCB main PCB and display connecting Main PCB and Wire and directly operation and display circuit. PCB is cut or connector display PCB with a tester. connect defective Defective LCD. terminal connection is contact terminal to bad. Lead Wire. Defective LCD. Check if all LCD are on when Replace display Refer to display Main PCB Test switch is PCB. circuit in circuit pressed (or when both freezer key and power freezer key are pressed at the same time for more than one second.) explanation.