Pfad: P:\02-systemeinheiten\TX150S2\TX150S2-e\TX150S2-e.k04 © Siemens Nixdorf Informationssysteme AG 1995 Removal/installation routines Fit assembly kit and rack-mount the server For mounting the left telescopic rail in the PRIMECENTER rack, the delivered support angle must first be mounted on the rear left support upright. The angle must be mounted level with the lower edge of the device. Ê Mount the support angle at the appropriate height on the left rear support upright as described in the technical manual of the PRIMECENTER rack. To fasten the telescopic rails, no flange nuts are necessary since the assembly brackets are equipped with threaded holes. For adjustment in each case two plug washers must be pre-mounted at the support uprights and the support angle: Ê Place the plug washers (1) in the holes of the support uprights and/or of the support angle at the marked attachment points. i For better orientation the height units are marked on the support uprights. U41057-J19-Z146-1-76 July 2004 02–TX150S2–143