Download SERVICE MANUAL

Transcript
16. Malfunction code
bizhub C450
16.6.18
Field Service Ver. 1.0 Mar. 2005
C2257: Cleaning Brush Motor's failure to turn
Relevant Electrical Parts
Cleaning Brush Motor (M22)
Control Board (PWB-MC)
WIRING DIAGRAM
Step
Action
Control Signal
Location
(Electrical
Component)
1
Check the M22 connector for proper connection and correct as necessary.
—
—
2
Check M22 for proper drive coupling and correct as necessary.
—
—
3
Check the PWB-MC connector for proper connection and correct as necessary.
PWB-MC PJ2MC-9 (DC24 V)
H-2
PWB-MC PJ37MC-3 (REM)
PWB-MC PJ37MC-6 (LOCK)
K-3
—
—
4
5
M22 operation check
Change PWB-MC.
16.6.19
C2258: Cleaning Brush Motor Turning at abnormal timing
Relevant Electrical Parts
Cleaning Brush Motor (M22)
Control Board (PWB-MC)
WIRING DIAGRAM
Step
1
2
M22 operation check
Location
(Electrical
Component)
PWB-MC PJ37MC-3 (REM)
PWB-MC PJ37MC-6 (LOCK)
K-3
—
—
Change PWB-MC.
16.6.20
Troubleshooting
Control Signal
Action
C2351: Toner Suction Fan Motor/K's failure to turn
Relevant Electrical Parts
Toner Suction Fan Motor/K (M23)
Control Board (PWB-MC)
WIRING DIAGRAM
Step
Control Signal
Location
(Electrical
Component)
1
Check the M23 connector for proper connection and correct as necessary.
—
—
2
Check M23 for proper drive coupling and correct as necessary.
—
—
PWB-MC PJ15MC-10 (REM)
PWB-MC PJ15MC-12 (LOCK)
C to D-21
—
—
3
4
350
Action
M23 operation check
Change PWB-MC.