ELECTRIC POWER NEEDED
Refer to the cabinet serial number plate to determine the proper voltage and frequency the machine requires
(domestically this requirement is 115 Volts, 60 Hertz). Domestic venders will operate properly at +/- 10% of the
specified voltage. For domestic models this is between 103 volts and 127 volts. The cabinet serial plate also indicates
the amperage of the vender. Single phase, alternating current is required. The vender must be plugged in its own
properly rated circuit with its own circuit protection (fuse/circuit breaker).
DO NOT USE AN EXTENSION CORD.
GROUND THE VENDER
The vender is equipped with a three wire power supply cord and MUST be plugged in a properly grounded outlet.
DO NOT REMOVE THE GROUND PIN OR IN ANY WAY BYPASS THE GROUNDING OF THE
VENDER.
If the outlet will not accept the power cord plug, contact an electrician to install a proper AC outlet.
WARNING:
Failure to comply with these instructions may subject the user to the risk of injury or
electrical shock which can be serious or fatal.
COIN CHANGERS AND OTHER ACCESSORIES
The SIID vender must have a coin changer installed and can have a bill acceptor installed. If the coin changer and
other accessories are not factory installed refer to the instructions received from the manufacturer of the coin changer
and other accessories for proper set-up and installation.
The SIID vender will support the following coin changers:
Multi-Drop Coin Mech (Domestic)
Coinco 9302GX
Mars TRC6510
BILL ACCEPTORS
If a bill acceptor is not factory installed, a bill acceptor interface harness must be ordered from Dixie-Narco. See the
chart below:
Bill Acceptor Interface Harnesses
Acceptor
Coca-Cola Venders
Coinco BA-30
*Multidrop Bus
* Also requires parts from acceptor manufacturer.
Note: Bill acceptors will be inhibited anytime the door interlock switch is in the center position (service mode enable)
even if service mode time out has occurred restoring the vender to normal operation.
Page 7 of 77