Chapter 2 Adjustments 2.5 Solder Bridges 13 Solder Bridges located on the left hand side of the drive are used to change internal and external functions on the MicroB. Below are the descriptions of the solder bridge functions. The drive is factory set with the following Solder Bridges and their function: S1 and S3 Normally open. (See section 5.7 “Ramp Time Adjustment”). S2 Normally closed. (See section 5.7 “Ramp Time Adjustment”). S4 Normally closed. If Open - disables the Encoder and Hall Effect velocity feedback. S5 Normally closed. If Open, install components for the Dynamic velocity costant CKV and RKV. Consult factory for proper use. S6 Normally closed. If Open, insert the GAIN resistor. (Static Gain). Standard value= 22ohm. Continued Service Manual 21