Download Fire Service Manual Volume 2 Fire Service
Transcript
Tactical Ventilation Ch pt r Chapter 5 - Forced Ventilation 1 General Ventilation efforts should be in concert with existing atmospheric conditions, taking advantage of natural ventilation whenever possible. However. in some situations, natural ventilation may be inadequate and may have to be supplemented or replaced by forced ventilation to provide a tenable atmosphere and to facilitate rescue operations. Forced ventilation refers to the use of fans, blowers, water sprays or other mechanical devices to create or redirect the flow of air inside the building so that the fire gases are forced out of the building. If forced ventilation is used to accelerate the effects of natural ventilation, it must be remembered that all the effects, both good and bad, may be accelerated. For this reason, it is essential that • it requires the use of a mechanical device, a power source and additional firefighters; • it can increase the intensity of a fire and lead to unwanted fire and smoke spread if incorrectlyapplied; • to clear large compartments, it requires a very large fan, or a number of smaller fans; • it can take time to set up; • in defensive ventilation operations, the limited airflow available means that systematic room-by-room clearance is necessary. The main techniques of forced ventilation are: • Positive Pressure Ventilation (PPV). PPV can be achieved by forcing air into a building using a fan. The effect of this will be to increase the pressure inside, relative to atmospheric pressure. PPV simply refers to blowing air in through the inlet vent. • Negative Pressure Ventilation (NPV). NPV refers to extracting the smoke and hot gases from the outlet vent. This will have the effect of reducing the pressure inside the building, relative to the atmospheric pressure. It can he achieved by fans or water sprays. • Heating Ventilation and Air Conditioning Systems (HVAC). Building HVAC systems can be designed so that, in the event of fire, they can be used as a smoke control system. • Powered Smoke and Heat Exhaust Systems. Dedicated fans and other devices which, usually triggered automatically, provide a smoke control system. the firefighters concerned have a good understanding of the principles of ventilation, and the behaviour of fire, before the use of forced ventilation is considered. The main advantages of forced ventilation are: • the ventilation objectives. i.e. smoke removal, restoration of a tenable atmosphere etc., are achieved more rapidly; • it makes horizontal ventilation more effective, so reducing the need for vertical ventilation; • it is less susceptible to erratic wind conditions, although it cannot overcome strong winds; • it is a more controllable form of ventilation. Its disadvantages are: Tactical Ventilation 39