Download LAGOON 450

Transcript
MOTORIZAÇÃO
ALARMES
In case of malfunction, the Power A system warns the operator
when it detects any fault by means of a sound code and by the
flashing of LEDs 2 and 3 respectively for the left and/or the right
motor.
N°
TITLE
Lever position sensor error.
1
Actuator communication error.
2
Running engagement error.
3
Throttle actuation error.
4
5
DESCRIÇÃO
Control station failure. If there is a second station, it is possible to use the
system, otherwise the system is set in a safety condition (throttles at minimum and shifts in neutral).
Short, Short, Short.
In the event of communication error, the system is set in a safety condition
(throttles at minimum and shifts in neutral). When the lever is put in idle position again, a restoration attempt is made and the system tries to take the
normal functionalities again. If the error persists, the system stops.
Short, Short, Long.
The system is set in a safety condition (throttles at minimum and shifts in
neutral). When the lever is put in idle position again, a restoration attempt is
made and the system tries to take the normal functionalities again. If the error persists, the system stops.
Short, Long, Short.
In the event of mechanical throttle failure (if it is present), the system waits
for two seconds and then tries to put itself in a safety condition (throttles at
minimum and shifts in neutral).
Short, Long, Long.
Troll actuation error.
Throttle warning.
6
Running engagement warning.
7
LAGOON 450
ALARME SONORO
8
MOTORIZAÇÃO
95
Long, Short, Short.
Warnings indicate external situations that could limit the system performance as low supply voltage or mechanical overloads of the cables connecting
actuators and motors. The system tries to maintain the functionalities. In the
event of persistent mechanical cable locking, the system does not signal a
warning any more but an alarm.
Long, Short, Long.
Warnings indicate external situations that could limit the system performance as low supply voltage or mechanical overloads of the cables connecting
actuators and motors. The system tries to maintain the functionalities. In the
event of persistent mechanical cable locking, the system does not signal a
warning any more but an alarm.
Long, Long, Short.