Download PTRL-NV PTRL-NV/HP - 3

Transcript
PTRL-NV & PTRL-NV/HP Technical and Maintenance Manual
2
FUSE
Fuse Block & Voltage Setting. Use a small
screwdriver to change fuse or voltage
setting. Turn block and place desired
operating voltage next to arrow
3
REMOTE CONTROL
DB9 communication line to control or
(Optional)
receive status of the transmitter. Baud
rate is 1200 Baud. On request, it may be
changed to 300, 600 or 2400 baud. A
program is
available on 5 1/4" or 3 1/2"
disk for IBM or compatible.
Plug is a standard DB9 female.
Pin 1
Not Connected
Pin 2
TXD
Pin 3
RXD
Pin 4
DSR *
Pin 5
GND
Pin 6
DTR *
Pin 7
CTS $
Pin 8
RTS $
Pin 9
Not Connected
* DSR and DTR are connected together
$ CTS and RTS are connected together
4
EXT 24V (+)
(Optional)
Positive terminal for EXT 24
5
EXT 24V (-)
(Optional)
Negative terminal for EXT 24V
6
FAN
Cooling fan
7
8
R.F. TEST -30dB R.F. Test point connector -30dB
U.S.A. AUDIO INPUT
U.S.A. audio inputs and telemetry
(Optional)
9
EXT. REF. IN
R.V.R. Elettronica S.r.l. (Bo)
External reference input (Not Used)
Pag. 22