Download manta - ABBAS, a.s.
Transcript
CIAS Elettronica S.r.l. Ed. 1.2 APPENDIX A The following is a list of the settings of some modems needed to remotely connect the barriers. As it can be seen, 2 different settings are provided for each type of modem, i.e., CENTRE (Operator Terminal which remotely connects the MANTA Barriers) and SITE (the RS485 interconnection network of the MANTA Barriers). Digicom Botticelli 56K V.90 Centre: at&f atx3 at%c3 at%e0 at+ms=9,1,9600,9600 at\n3 ate0 at&w Digicom Leonardo56 Load default parameters. Engaged tone detection. Compression MNP5 &V.42 bis. Auto-retrain disabled. Make the connection only at 9600 bps. Error correction V.42 LAPM/MNP. Disable echo of controls. Store parameters. Site: at&f atx3 at%c3 at%e0 at+ms=9,1,9600,9600 at\n3 ate0 ats0=1 at&w Load default parameters. Engaged tone detection. Compression MNP5 &V.42 bis. Auto-retrain disabled. Make the connection only at 9600 bps. Error correction V.42 LAPM/MNP. Disable echo of controls. Automatic reply after one ring. Store parameters. VACF1433VQE Centre: at&f atx3 at%c0 at%e0 at\n5 ate0 at&w Load default parameters. Engaged tone detection. Remove compression MNP5 &V.42 bis. Auto-retrain disabled. Error correction MNP. Disable echo of controls. Store parameters. Site: at&f atx3 at%c0 at%e0 at\n5 ats0=1 ate0 at&w Installation Handbook Load default parameters. Engaged tone detection. Remove compression MNP5 &V.42 bis. Auto-retrain disabled. Error correction MNP. Automatic reply after one ring. Disable echo of controls. Store parameters. page 50 of 51 MANTA 50 – 80