Download 3 - Costan
Transcript
12.2 REPLACING THE POWER CORD In the event that the power cord is damaged, to prevent any possible hazard, only have it be replaced by the manufacturer's servicing personnel or by experts. 12.3 REPLACING THE FUSE IN THE AUXILIARY ELECTRICAL OUTLET The display cabinet is supplied including a spare fuse which is located in the recess where the power outlet is. Caution: 16 A have been exceeded; check the wiring. To replace the protection fuse it is necessary to completely extract the outlet (fig. 1) Follow the instructions below: • Unscrew the four screws (fig. 2). • Pull the socket out completely. • Unscrew the fuse holder and replace the fuse using an identical-type fuse (fuse type 6,3x32 16A DELAY-TYPE) • Reassemble it all correctly. Fig . 1: auxiliary socket Fig . 2: detail of socket 12.4 REPLACING THE CONDENSER FAN The jobs described in this chapter must be performed by qualified personnel. Remove the condenser guard (see chapter 11.1 “condenser cleaning") Fig . 1: detail of work point Fig . 2: open slowly 50