Download Operator`s manual
Transcript
Features, care, cleaning and maintenance Calibration If it is wanted to make a equipement calibration, check software operator's manual available in http:// www.terragene.com.ar/productos/control-de-infecciones/control-de-procesos-de-esterilizacion/incubadoras/ic10-20fr/ Features, care, cleaning and maintenance Time zone change Cancel time zone change Hours setting 3-To advance time, press TEMP button as many times as hours you need to advance. To delay time press SOUND button as many times as hours you need to delay. Advance Delay To cancel change time zone process and not save changes, disconnect power source. NOTE: Lights corresponding to 1 to 10 incubation/ reading positions indicate the digit value which is set. Lights from 1 to 9 indicate digit value from 1 to 9. Light 10 indicates 0 value. In time setting mode, light 1 from Pro sector will turn on to indicate ten hour modification. IMPORTANT: 24-hour format. Time zone change mode This function allows you to advance or delay the internal incubator clock in order to adopt a different time zone. Enter time zone change mode 1-De-energize the incubator. NOTE: 37 °C light indicates a.m. and 60 °C light indicates p.m. Ten hours setting (Hh:mm) 3-The blue light number 1 corresponding to Pro sector should be on. If any other light from Pro sector is on, press PRO button as many times as necessary to turn on the blue light number 1. This indicates ten hour setting. Time setting mode Time setting functionality allows you establish a specific time regardless of incubator current time. a.m. p.m. Enter time setting mode 1-De-energize the incubator. 2-Press and hold both TIME buttons simultaneously and energize the equipment. A beep will be emitted to indicate access to time zone change. 4-To increase ten hours value, press TEMP button. To reduce ten hours value, press SOUND button. NOTE: the possible values for ten hour are 0, 1 and 2. Advance Complete time zone change Delay 4-To save changes press and hold PRO button for three seconds. A beep will sound indicating that process has been completed successfully. A ticket with the new set time will be printed. 2-Press and hold both TIME buttons and TEMP button simultaneously and energize the equipment. A beep will be emitted to indicate access to time setting mode. NOTE: a green light will turn on in one of the incubation/reading position. This number corresponds to the current incubator time. IC10/20FR Page 12 Unit hours setting (hH:mm) 5-Press PRO Button to turn on the blue light number 2. This indicates unit hours setting. If any other light from Pro sector is on, press PRO button as many times as necessary to turn on the blue light number 2. IC10/20FR Page 13