Download Ver/Abrir
Transcript
Miller H Series Hydraulic Cylinders LRT Cylinders Description Transducer Performance Specifications Miller Fluid Power Position Sensing Cylinders (PSC) with LRT linear resistive transducers provide simple, reliable, and cost-effective position sensing. Resolution.......................................Infinite Linearity ..........................................0.1% to 46 inches 1% to 120 inches Repeatability ...................................0.001 inch minimum Maximum Speed .............................20 inches/second Maximum Pressure.........................3000 PSI Temperature Range.........................-40˚F to 180˚F 300˚F Optional Minimum Durability ........................500 million inches of stroke (for transducer) The LRT consists of a resistance element assembly internal to the cylinder rod with a wiper carriage installed in the piston head. As the wiper moves with the piston, an electrical circuit is created between the upper resistive element and the lower collector strip. Wiper voltage is directed from the collector through wiring to an electrical connector. Position sensing is then determined by the analog output voltage proportional to the wiper (piston) position on the resistive element. Note: Standard LRT design not suitable for use with Phosphate Ester or high water content fluids. Design Features CYLINDER ROD High performance, low cost design allows for the addition of a position sensing device to heavy duty hydraulic cylinders. Infinite resolution, excellent linearity, resistance stability, and long life, provides increased productivity, improved reliability, and repeatable tolerances. TO ELECTRONIC CONTROL WIPER CARRIAGE ASSEMBLY Simple analog feedback signals interface with motion controllers without complex transducer signal conditioning, thus offering minimum start-up time and ease of use for engineers or operators. ELECTRICAL CONNECTOR PRESSURE PORT PISTON LINEAR RESISTANCE ROD ASSEMBLY Compact transducer design is protected in the cylinder from severe environments and possible damage. Slide-off wiper carriage allows for fast and economical cylinder seal retrofits including snap-ring replacement of the wiper carriage in the piston, if necessary. RESISTANCE MATERIAL COLLECTION STRIP CARRIAGE SNAP RING Economical position sensing in a NFPA hydraulic cylinder with only an extension of one (1) inch overall length provides for standard mounting options in existing applications. WIPERS LINEAR RESISTANCE ROD ASSEMBLY PRESSURE PORT WIPER CARRIAGE ASSEMBLY High pressure rating and solderless electrical connector are options offered as standard features for maximum package integrity and design flexibility. High temperature (300˚F) versions are available. Standard Specifications Transducer Electrical Options Method of Position Sensing............Linear Resistive Transducer LRT Maximum Stroke.............................120 inches Minimum Rod Diameter..................5⁄8 inch up to 20 inches stroke Bore Sizes .......................................11⁄2 to 8 inches Mounting ........................................All NFPA styles Input Voltage Requirements............5 to +50VDC maximum Analog Output Voltages ..................0 VDC to + 10 VDC (with additional -10 VDC to + 10 VDC electronic controllers) 4 to 20 MA optional 69