Download 4 - Innova
Transcript
Retrieving Codes 4 KOEO SELF TEST (MCU SYSTEMS) ■ In-Line 4 and In-Line 6 with canister control valve: Remove hose from connector port B. Reconnect after testing is completed. ■ V-6 and V-8: Remove PCV valve: Reconnect after testing is completed. ■ 2.3L with GK code: Locate the anti-backfire vacuum switch tee behind the MCU module and remove the cap. Reconnect after testing is completed. ■ 2.3L with EGR vacuum load control valve: Cover vacuum valve vent holes with tape. Remove the tape after testing is completed. ■ 4.2L with vacuum delay valve: Uncap restrictor in Thermactor Air Diverter (TAD) solenoid vacuum line. Reconnect after testing is completed. ■ 5.8L with vacuum delay valve: Uncap restrictor in Thermactor Air Bypass (TAB) solenoid vacuum line. Reconnect after testing is completed. KEY ON ENGINE OFF (KOEO) SELF TEST (MCU SYSTEMS) • The "Preliminary Procedures" (page 65) must be completed before performing the KOEO Self Test • Always observe safety precautions before and during testing process. • ALWAYS check Code Reader battery before retrieving fault codes. • Fix any known mechanical problems before this test. 1. Warm-up engine to normal operating temperature before this test. 2. Turn ignition off. 3. Turn the Code Reader switch to OFF then connect it to the vehicle's test connector. ■ Chapter 4 MCU Systems have one six pin connector only. 66