Download Manitowoc - Webstaurant Store

Transcript
Section 2
Installation Instructions
Location of Ice Machine
Installation Requirements
The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
•
The ice machine and bin must be level.
•
Vent the ice machine and bin drains separately.
•
Bin drain termination must have an air gap.
•
A backflow preventer is required on water inlet lines.
•
The location must be free of airborne and other
contaminants.
•
The air temperature must be at least 50°F (10°C), but
must not exceed 110°F (43°C).
•
The ice machine and bin must be sanitized after
installation.
•
The water temperature must be at least 40°F (4°C),
but must not exceed 90°F (32°C).
•
•
The location must not be near heat-generating
equipment or in direct sunlight.
Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.
•
•
The location must be capable of supporting the
weight of the ice machine and a full bin of ice.
Routine adjustments and maintenance procedures
outlined in this manual are not covered by the
warranty.
•
The location must allow enough clearance for water,
drain and electrical connections in the rear of the ice
machine.
•
The location must not obstruct airflow through or
around the ice machine.
CLEARANCE REQUIREMENTS
RF0244/RF0266
RF0385/RF0388
RF0399/RF0644
RNS0244/RNS0385
Top
Sides
Back
RCU Units
Front/Back
Sides/Top
Air-Cooled
Water-Cooled
0” (0 cm)
2” (5 cm)
8" (20 cm)
0” (0 cm)
2” (5 cm)
8" (20 cm)
AirCooled
WaterCooled
QuietQube
Air-Cooled
8" (20 cm)
5" (13 cm)
8" (20 cm)
5" (13 cm)
0" (0 cm)
0" (0 cm)
Remote Condensing Unit
24" (61 cm)
6" (15.2 cm)
NOTE: Water-cooled/Remote condensing units only - there is no minimum
clearance required. This value is recommended for efficient operation and
servicing only.
Part Number 000007644 2/12
Series
Ice Machine
RFS1279R
RFS2379R
Heat of Rejection
7850
15700
B.T.U./Hour
NOTE: Allowance must be made for removal when the ice machine is built in.
Monthly removal of the top panel is required for cleaning & sanitizing.
RFS0300/RFS0650
RFS1200/RF1200
RFS2300/RF2300
RNS0300
Top/Sides
Back
Ice Machine Heat of Rejection
Ice machines, like other refrigeration equipment, reject
heat through the condenser. It is helpful to know the
amount of heat rejected by the ice machine when sizing
air conditioning equipment.
This information is also necessary when evaluating the
benefits of using water-cooled or remote condensers to
reduce air conditioning loads. The amount of heat added
to an air conditioned environment by an ice machine
using a water-cooled or remote condenser is negligible.
Knowing the amount of heat rejected is also important
when sizing a cooling tower for a water-cooled
condenser. Use the peak figure for sizing the cooling
tower.
Rack Unit Connection Size
Model
Suction Line
Liquid Line
RFS1279R
5/8 inch
(15.9 mm)
3/8 inch
(9.5 mm)
RFS2379R
3/4 inch
(19 mm)
1/2 inch
(12.7 mm)
7