Download Manitowoc - Webstaurant Store
Transcript
Section 2 Installation Instructions Location of Ice Machine Installation Requirements The location selected for the ice machine must meet the following criteria. If any of these criteria are not met, select another location. • The ice machine and bin must be level. • Vent the ice machine and bin drains separately. • Bin drain termination must have an air gap. • A backflow preventer is required on water inlet lines. • The location must be free of airborne and other contaminants. • The air temperature must be at least 50°F (10°C), but must not exceed 110°F (43°C). • The ice machine and bin must be sanitized after installation. • The water temperature must be at least 40°F (4°C), but must not exceed 90°F (32°C). • • The location must not be near heat-generating equipment or in direct sunlight. Local water conditions may require treatment of the water to inhibit scale formation, filter sediment, and remove chlorine odor and taste. • • The location must be capable of supporting the weight of the ice machine and a full bin of ice. Routine adjustments and maintenance procedures outlined in this manual are not covered by the warranty. • The location must allow enough clearance for water, drain and electrical connections in the rear of the ice machine. • The location must not obstruct airflow through or around the ice machine. CLEARANCE REQUIREMENTS RF0244/RF0266 RF0385/RF0388 RF0399/RF0644 RNS0244/RNS0385 Top Sides Back RCU Units Front/Back Sides/Top Air-Cooled Water-Cooled 0” (0 cm) 2” (5 cm) 8" (20 cm) 0” (0 cm) 2” (5 cm) 8" (20 cm) AirCooled WaterCooled QuietQube Air-Cooled 8" (20 cm) 5" (13 cm) 8" (20 cm) 5" (13 cm) 0" (0 cm) 0" (0 cm) Remote Condensing Unit 24" (61 cm) 6" (15.2 cm) NOTE: Water-cooled/Remote condensing units only - there is no minimum clearance required. This value is recommended for efficient operation and servicing only. Part Number 000007644 2/12 Series Ice Machine RFS1279R RFS2379R Heat of Rejection 7850 15700 B.T.U./Hour NOTE: Allowance must be made for removal when the ice machine is built in. Monthly removal of the top panel is required for cleaning & sanitizing. RFS0300/RFS0650 RFS1200/RF1200 RFS2300/RF2300 RNS0300 Top/Sides Back Ice Machine Heat of Rejection Ice machines, like other refrigeration equipment, reject heat through the condenser. It is helpful to know the amount of heat rejected by the ice machine when sizing air conditioning equipment. This information is also necessary when evaluating the benefits of using water-cooled or remote condensers to reduce air conditioning loads. The amount of heat added to an air conditioned environment by an ice machine using a water-cooled or remote condenser is negligible. Knowing the amount of heat rejected is also important when sizing a cooling tower for a water-cooled condenser. Use the peak figure for sizing the cooling tower. Rack Unit Connection Size Model Suction Line Liquid Line RFS1279R 5/8 inch (15.9 mm) 3/8 inch (9.5 mm) RFS2379R 3/4 inch (19 mm) 1/2 inch (12.7 mm) 7