Download MINIDUE FILTRO

Transcript
MINIDUE FILTRO - ENGLISH
A3 TROUBLESHOOTING
Problem
No
consumption
®
of
AcquaSIL
Cause
Solution
No water flow in the pipe.
Check for the presence of water in
2/15 .
the distribution line by opening a
tap downstream of the pump.
Flow meter impeller blocked.
Call authorized center.
Defective injection valve.
®
.
®
AcquaSIL 2/15 refill empty.
When the AcquaSIL
2/15
reserve in the refill is depleted,
the installation is no longer
protected.
Replace the empty refill bag.
Poor water flow during uses.
Filter partially
clogged.
completely
Perform an ordinary cleansing by
opening the drain valve for a few
seconds. If the problem persists
close the ball valve, open the ring
nut, extract the filter cartridge and
clear it up. Reassemble the
cartridge following the reverse
procedure. If the problem persists
please contact Acqua Brevetti 95
s.r.l.
The ball valve doesn’t close
properly.
Valve blocked because of scale
and dirt.
Call an Acqua Brevetti 95 s.r.l.
authorized center.
or
A4 MINIDUE FILTRO AND DEPLETED REFILL BAGS DISPOSAL
®
The AcquaSIL 2/15 disposable refills are made of plastic multiplayer non recyclable material and they have
to be treated like that. MiniDUE FILTRO pump is made of plastic non recyclable material and it has to be
disposed according to the current legislation. In case of doubt please contact the waste management
service.
A5 MINIDUE FILTRO PUMP LABELLING
On the upper side of the equipment there is an identification label of the purchased product. In particular the
serial number must be copied on the warranty certificate.
Serial number
Production date (month/year)
MAN 117
AAA 00123
0X 0Y
PAG.E-6