Zodiac® Nature2® Fusion Soft | Installation and Operation Manual
Control Valve Installation Options
Install between the inlet
and discharge side of
bypass plumbing
FUSIONM
or
APUREM
or
PureLinkTM
or
Existing AquaPure®
Power Pack
Optional ChemLink or
other ORP Control
Install on the inlet
side of the vessel
Heater
Pump
Flow/Temperature/
Salinity Sensor
Filter
Nature2 Fusion Soft
Pool Intake
Spa Intake
Flow
Flow
Flow/Temperature/
Salinity Sensor
Pool Return
Figure 5.
Spa Return
Example of Bypass Installation
9. Fully open any closed valves, including the control
valve, and start the pump diverting water through
the new bypass.
3.
10. Check the vessel and system for leaks.
4. Install a 3-way valve in the return line to allow
water to be diverted/restricted to the Nature2
Fusion Soft and water feature line.
11. Adjust control valve so that flow rate through the
vessel is between a minimum of 114 lpm (30 gpm)
and a maximum of 455 lpm (120 gpm).
3.6
Split-Return Installation
If the vessel is used with a water feature line system, it
must be installed in a split-return configuration or vessel
damage may occur.
1.
Make sure the pool pump is turned off.
2.
Install the Nature2 cartridge..
Locate a suitable section of pipe to install
the vessel that conforms to the installation
requirements outlined in Section 3.2.
5. Fully open any closed valves, including the 3-way,
to allow unrestricted flow to the Nature2 Fusion
Soft and water feature line.
6.
Hand tighten all unions, sensors, and collars.
CAUTION
Be careful not to get finger caught between inlet
union and plug when tightening as this may cause an
injury.