IMPORTANT USER ASSISTANCE INFORMATION BEFORE USING PERIOWAVE™, PLEASE READ THESE INSTRUCTIONS CAREFULLY WARNINGS AND PRECAUTIONS: CAUTION – USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY RESULT IN HAZARDOUS RADIATION EXPOSURE The laser base station is equipped with the following laser radiation warning labels: • Use only the power supply that was provided, otherwise you may damage your PERIOWAVE™ system and invalidate your warranty; similarly, only approved PERIOWAVE™ accessories are to be used with the PERIOWAVE™ system. • The PERIOWAVE™ system is NOT waterproof. Do not submerge any part of the PERIOWAVE™ base station or main power supply in water. • The PERIOWAVE™ system is designed for indoor use ONLY. • It is recommended that you charge the batteries for 4 hours before the first use. • The PERIOWAVETM system has no compatibility with other medical devices. • Only approved PERIOWAVE™ parts may be connected to the system (including power supply, base station, battery, and footswitch). No other device may be connected to any of the sockets without prior written permission from the manufacturer. Non-compliance with these instructions may damage equipment, void any warranty, and be dangerous. 2 • The light-emitting aperture is at the distal end of the handpiece. • When the laser base station is not in use, it should be protected against unqualified use, for example by removal of the key from the key control switch (Figure 9). • Before performing any cleaning or maintenance procedures on the laser base station, fiber optics cable, or handpiece, the power supply connector located on the rear panel of the laser base station should be disconnected (Figure 9). • Do not use any product to clean the fiber optic components of the PERIOWAVE™ system other than those supplied with the system. The use of any other product may affect the transparency of the optics, causing a reduction of the laser power delivered to the treatment site and a reduction of clinical efficacy. • This device is not suitable for use in the presence of flammable mixtures. • Do not modify or alter any component of the PERIOWAVE™ system. • The operator and patient should always wear laser safety eyewear when using the PERIOWAVE™ system. Two pairs of PERIOWAVE™ laser safety eyeglasses are included. • Use only the PERIOWAVE™ treatment kits (PW3100 and PW3200) containing the photosensitizing solution provided with the PERIOWAVE™ system. This solution is specially formulated to be effective with the operating laser wavelength, power, and exposure time. • Do not operate the PERIOWAVE™ system without the handpiece attached. • Do not autoclave any component other than the handpiece; this may damage materials and/or components. • Do not operate the PERIOWAVE™ system without the lightdiffusing tip attached to the handpiece, except during the test procedure. • Do not reuse any component intended and identified for single use only. UG1000 Rev B