Nomenclature
 CAUTION
Model:
INPUT:
OUTPUT:
Electrical connections
Do not inspect components unless the lamp is off
See manual for correct installation and operation
EDX-040-21-E
AC 1 phase 50 / 60Hz
AC 3 phases 0 – 200Hz
Motor Rating: 0.5HP / 0.4KW
VOLTAGE:
200 – 240V (+10%, -15%)
VOLTAGE:
0 - VIN
IRMS : 5.4A
IRMS : 3.1A
Braking Unit
(optional)
IP20 / UL Open Type (rated -10˚C to 50˚C Ambient)
IMO Precision Controls Ltd
WARNING: THIS PRODUCT MUST BE EARTHED!
EDX - 040 -
2
1
-
Power terminals
1Ø 100-120V
1/3Ø 200-240V
3Ø 380-480V
E
L1 (L)
L2
L3 (N)
T1
T2
T3
PE
PE
Motor
iDrive
Enclosure
IP65 + water &
N4S
dust proof switch
IP65 without water &
N4
dust proof switch
IP20
Power (kW)
0.2
020
0.4
040
0.75
075
1.5
150
2.2
220
RA (1)
(3) 24V
(4) S1
(5) S2
(6) S3
(7) S4
(8) COM
Multi function
digital input ‘x’
12/24Vdc
PNP common
Multi function
relay output
RB (2)
SW1: digital signal
selection (NPN/PNP)
SW2: control signal
selection (0-10V/4-20mA)
1 2
E
100V
200V
400V
NPN common
1
2
4
1
3
No Filter
EMC Filter built in
Multi function analogue input
• Set speed
• PID feed
10kΩ
back input
1Phase
3 Phase
FM
(9) +10V
(10) AIN
(11) COM
S5
S6
(12) FM+
T+
• Option interface
• Multi function I/O
card (2 in, 1 out)
• Remote Keypad
T24V/0.6A
Mechanical installation
Standard IP20 type iDrive EDX is designed to be mounted inside a grounded steel enclosure.
The ambient temperature inside the enclosure must not exceed 50˚C or the lifetime of iDrive may be
reduced and manufacturers warranty voided.
If necessary use additional cooling fans and filtered ventilation ports in the enclosure.
Installation must be upright, mounting onto a grounded steel back plate.
Fixing can be via the 4 mounting holes / slots or onto standard DIN rail using the built-in DIN rail clip.
4
Note 1:
Connect point x to either :Terminal 3 (internal +24VDC) for PNP mode (positive switching) OR
Terminal 8 (Common 0V) for NPN mode (negative switching)
Note 2:
External 24VDC may be used to supply the external contacts at point ‘x’
If so then connect the 0V of the external supply to Common (terminal 8)
5