Sealing is carried out using the enclosed cellular rubber seal (23) without any further sealing combined. In the case of greater roof thicknesses, first connect the ducts to the cowl from the outside. Pass cellular rubber seal (23) and clamp (19) over the ducts. Press together the end of the exhaust duct (4) so that winding touches winding and slide over the O-ring onto the connection fitting (24). Fasten using clamp (19) in such a way that the bead edge of the clamp grasps around the collar. Slide combustion air duct (9) over the connection fitting (25) and fasten with clamp (11). Fasten cowl part (26) with screws (27). Screw on cowl cover (28) with three screws (29). Always close the deck cowl when the water heater is not being operated. Attention: A new O-ring must always be installed after any disassembly! 4 Installation of safety/drain valve Fig: E. Install safety/drain valve (34) at a place which is easily accessible, near the water heater. Drill hole with 18 mm diameter and pass through discharge socket with hose (31). Fasten safety/ drain valve with 2 screws. 5 Water connection Hoses with an inside diameter of 10 mm are required for the connection to the water heater and safety/drain valve. In order to ensure a satisfactory cold water connection, free of kinks, wi recommend the elbow connection (Art. no. 70150-01, Fig. E: 35). For the hot water connection we recommend the elbow connection (Art. no. 34150-01) with integrated breather valve (Fig. E: 36). With rigid lines (e.g copper pipe with 10 mm outside diameter) on the water heater, use olive couplings. Provide a connection at the safety/drain valve with hose pieces of approx. 10 cm in length. Attention: All hose connections must be secured with hose clamps (also cold water hoses)! The thermal expansion of the water can cause 9 pressures of up to 3.5 bar before the safety valve reacts (also in submergible pumps). For fastening the hoses to the wall or floor we recommend the hose clips (Art. no. 4071000). If a gas heater is installed, the water hoses can be routed on the hot air distributer pipes using the hose clips, thus providing protection against frost. 1. Drill a hole of 22 mm diameter for the cable leadthrough and pass the cable through. 2. Fasten control panel using 2 screws. For „flush-mounted“ installation of the control panel, Truma provides a control panel frame as special equipment (Art. no. 39980-01). suitable for charging lead batteries. Other charging devices are only to be used with a car battery acting as buffer. Power packs and power supply units must have a stabilised 12 V-output (ripple content less than 1 Volt). 8 Gas connection Fig. E: Route water hoses as short as possible and without kinks. 7 Electrical connection 12 V Fig. C: The 8 mm gas supply line is connected to the connection fitting (42) with olive couplings. Carefully hold in place with a second wrench when tightening! Attention: Route all water lines in descending manner to the safety/drain valve so that they can be completely drained if there is a risk of frost! Always disconnect the appliance from the power supply prior to working on electrical components. It is not sufficient to just switch off at the control panel! Before connecting to the water heater make sure that the gas lines are free from dirt, chips and such! 1. Connect cold water supply (30) to safety/drain valve (34). The direction of flow is not important. The appliance must be disconnected from the vehicle main power supply when carrying out any electric welding work on the vehicle body. 2. In submergible pumps assemble the Truma nonreturn valve (45) between pump and the first branch (arrow indicates direction of flow). This is not necessary in pressure pumps with already installed non-return valve. 3. Provide hose connection (32) for cold water supply between safety drain/valve and supply on the water heater. 4. Route hose (33) from upper water heater connection to the hot water consumers. Route the hot water pipes to the taps ascending as much as possible, however at least horizontal from the water heater connection! 5. Fig. E: If the hot water pipes are partly routed on the floor, or lower, it is necessary to install the Truma elbow connection (36) (Art. no. 34150-01), as shown in Fig. E, with integrated breather valve, to ensure the draining of the water. Nonobservation of this point means the heater is not drained properly and there is a risk of damage through frost! 6 Installation of the control panel Choose a place where the control panel is not exposed to direct radiant heat. Length of connecting cable: 2.5 m. A 5-meter long extension cable is available, if necessary (Art. no. 70000-53500). Attention: If the connections are transposed there is a risk of cable burning. This also rules out any guarantee or liability claims. Fig H: Unscrew cover (39) from the electronic control unit. Slide cable connector of control panel (38) onto the p.c.b.. The electrical connec-tion is made at terminal (40) (red = positive, blue = negative), for this purpose press with a small screwdriver from above and push in cable from the front. Connect to fused vehicle mains (central electrical equipment 5 - 10 A) using a 2 x 1.5 mm2 cable. Negative cable to central earth. With lengths of over 6 m use a cable 2 x 2.5 mm2. If connecting directly to the battery, the positive and negative cable must be fused. Screw cover (39) back on. There are to be no other consumers connected to the supply line! The water heater fuse (0.8 A slow-acting, DIN 41662) is on the p.c.b. (41). When using power packs, observe that the appliance is only to be operated with safety extra-low voltage according to EN 60742! Note: For the connection of several 12 V appliances we recommend the electronically controlled Truma power pack NT (Art. no. 39900-01). The Truma power pack (6 A continuous current) is also Route the pipes in such a way that the appliance can be removed again for servicing. In areas frequented by people, keep the number of parting connections in the gas supply line to an technically feasible minimum. The gas system must comply with the technical and administrative regulations of the country in which the appliance is used (in Germany, for example, the DVGW form G 607 or G 608). 9 Special version BMN 10, BMN 14 with additional electric heating 230 V, 450 W Attention: The electrical connection is only to be carried out by an expert (in Germany, acc. to VDE 0100, Section 721). The information given here is not intended as information for the layman, rather it is to for assisting the assigned expert, as additional information, when connecting the appliance! The connection to the power supply is by means of a cable 3 x 1.5 mm2 to a splitting box (e.g. flexible sheathed cable H05VV-F). Always pay attention to connect carefully with the correct colours! For maintenance and repair work a disconnecting device must be provided on the vehicle for all-pole disconnection from the power supply, with at least 3 mm contact clearance. Figure D: Install control device (43) in such a way that it is not affected by direct