Download Bootsboiler

Transcript
Sealing is carried out using
the enclosed cellular rubber
seal (23) without any further
sealing combined.
In the case of greater roof
thicknesses, first connect the
ducts to the cowl from the
outside.
Pass cellular rubber seal (23)
and clamp (19) over the
ducts.
Press together the end of the
exhaust duct (4) so that winding touches winding and
slide over the O-ring onto the
connection fitting (24). Fasten
using clamp (19) in such a
way that the bead edge of
the clamp grasps around the
collar. Slide combustion air
duct (9) over the connection
fitting (25) and fasten with
clamp (11).
Fasten cowl part (26) with
screws (27). Screw on cowl
cover (28) with three screws
(29). Always close the deck
cowl when the water heater
is not being operated.
Attention: A new O-ring
must always be installed after
any disassembly!
4
Installation of
safety/drain valve
Fig: E. Install safety/drain valve (34) at a place which is
easily accessible, near the
water heater. Drill hole with
18 mm diameter and pass
through discharge socket with
hose (31). Fasten safety/ drain
valve with 2 screws.
5
Water connection
Hoses with an inside diameter of 10 mm are required for
the connection to the water
heater and safety/drain valve.
In order to ensure a satisfactory cold water connection,
free of kinks, wi recommend
the elbow connection (Art.
no. 70150-01, Fig. E: 35). For
the hot water connection we
recommend the elbow connection (Art. no. 34150-01)
with integrated breather valve
(Fig. E: 36).
With rigid lines (e.g copper
pipe with 10 mm outside diameter) on the water heater,
use olive couplings. Provide a
connection at the safety/drain
valve with hose pieces of
approx. 10 cm in length.
Attention: All hose connections must be secured with
hose clamps (also cold water
hoses)! The thermal expansion of the water can cause
9
pressures of up to 3.5 bar
before the safety valve reacts
(also in submergible pumps).
For fastening the hoses to the
wall or floor we recommend
the hose clips (Art. no. 4071000). If a gas heater is
installed, the water hoses can
be routed on the hot air distributer pipes using the hose
clips, thus providing protection against frost.
1. Drill a hole of 22 mm diameter for the cable leadthrough and pass the cable
through.
2. Fasten control panel using
2 screws.
For „flush-mounted“ installation of the control panel,
Truma provides a control
panel frame as special equipment (Art. no. 39980-01).
suitable for charging lead
batteries. Other charging
devices are only to be used
with a car battery acting as
buffer. Power packs and power supply units must have a
stabilised 12 V-output (ripple
content less than 1 Volt).
8
Gas connection
Fig. E: Route water hoses as
short as possible and without
kinks.
7
Electrical
connection 12 V
Fig. C: The 8 mm gas supply
line is connected to the connection fitting (42) with olive
couplings. Carefully hold in
place with a second wrench
when tightening!
Attention: Route all water
lines in descending manner to
the safety/drain valve so that
they can be completely
drained if there is a risk of
frost!
Always disconnect the
appliance from the power
supply prior to working on
electrical components. It is
not sufficient to just switch
off at the control panel!
Before connecting to the water heater make sure that the
gas lines are free from dirt,
chips and such!
1. Connect cold water supply
(30) to safety/drain valve (34).
The direction of flow is not
important.
The appliance must be disconnected from the vehicle
main power supply when carrying out any electric welding
work on the vehicle body.
2. In submergible pumps
assemble the Truma nonreturn valve (45) between
pump and the first branch
(arrow indicates direction of
flow). This is not necessary in
pressure pumps with already
installed non-return valve.
3. Provide hose connection
(32) for cold water supply between safety drain/valve and
supply on the water heater.
4. Route hose (33) from
upper water heater connection to the hot water consumers. Route the hot water
pipes to the taps ascending
as much as possible, however
at least horizontal from the
water heater connection!
5. Fig. E: If the hot water pipes are partly routed on the
floor, or lower, it is necessary
to install the Truma elbow
connection (36) (Art. no.
34150-01), as shown in
Fig. E, with integrated breather valve, to ensure the draining of the water. Nonobservation of this point
means the heater is not
drained properly and there
is a risk of damage through
frost!
6
Installation of the
control panel
Choose a place where the
control panel is not exposed
to direct radiant heat. Length
of connecting cable: 2.5 m.
A 5-meter long extension
cable is available, if necessary
(Art. no. 70000-53500).
Attention: If the connections are transposed there
is a risk of cable burning.
This also rules out any
guarantee or liability
claims.
Fig H: Unscrew cover (39)
from the electronic control
unit. Slide cable connector of
control panel (38) onto the
p.c.b.. The electrical connec-tion is made at terminal (40)
(red = positive, blue = negative), for this purpose press
with a small screwdriver from
above and push in cable from
the front. Connect to fused
vehicle mains (central electrical equipment 5 - 10 A) using
a 2 x 1.5 mm2 cable.
Negative cable to central
earth. With lengths of over
6 m use a cable 2 x 2.5 mm2.
If connecting directly to the
battery, the positive and negative cable must be fused.
Screw cover (39) back on.
There are to be no other consumers connected to the supply line!
The water heater fuse
(0.8 A slow-acting,
DIN 41662) is on the p.c.b.
(41).
When using power packs,
observe that the appliance is
only to be operated with
safety extra-low voltage according to EN 60742!
Note: For the connection of
several 12 V appliances we recommend the electronically
controlled Truma power pack
NT (Art. no. 39900-01). The
Truma power pack (6 A
continuous current) is also
Route the pipes in such a way
that the appliance can be
removed again for servicing.
In areas frequented by people, keep the number of parting connections in the gas
supply line to an technically
feasible minimum.
The gas system must comply
with the technical and administrative regulations of the
country in which the appliance is used (in Germany, for
example, the DVGW form
G 607 or G 608).
9
Special version
BMN 10, BMN 14
with additional
electric heating
230 V, 450 W
Attention: The electrical
connection is only to be carried out by an expert (in Germany, acc. to VDE 0100, Section 721). The information given here is not intended as
information for the layman,
rather it is to for assisting the
assigned expert, as additional
information, when connecting
the appliance!
The connection to the power
supply is by means of a cable
3 x 1.5 mm2 to a splitting box
(e.g. flexible sheathed cable
H05VV-F).
Always pay attention to connect carefully with the correct
colours!
For maintenance and repair
work a disconnecting device
must be provided on the vehicle for all-pole disconnection from the power supply,
with at least 3 mm contact
clearance.
Figure D: Install control
device (43) in such a way that
it is not affected by direct